73 / 92 page ![]() Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features Datasheet SMSC EMC6D103 73 Revision 0.3 (03-01-07) DATASHEET 8.2.21 Registers 6A-6Ch: Absolute Temperature Limit These registers become read only when the Lock bit is set. Any further attempts to write to these registers shall have no effect. In Auto Fan mode, if any zone associated with a PWM output exceeds the temperature set in the Absolute limit register, all PWM outputs will increase their duty cycle to 100% except those that are disabled via the PWM Configuration registers. This is a safety feature that attempts to cool the system if there is a potentially catastrophic thermal event. If an absolute limit register set to 80h (-128 °c), the safety feature is disabled for the associated zone. That is, if 80h is written into the Zone x Temp Absolute Limit Register, then regardless of the reading register for the zone, the fans will not turn on-full based on the absolute temp condition. Default =100 °c=64h. When any fan is in auto fan mode, then if the temperature in any zone exceeds absolute limit, all fans go to full, including any in manual mode, except those that are disabled. Therefore, even if a zone is not associated with a fan, if that zone exceeds absolute, then all fans go to full. In this case, the absolute limit can be chosen to be 7Fh for those zones that are not associated with a fan, so that the fans won't turn on unless the temperature hits 127 degrees. 50 °c50 32h . . . . . . . . . 127 °c127 7Fh Table 8.38 egisters 6A-6Ch: Absolute Temperature Limit Register Address Read/ Write Register Name Bit 7 (MSb) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSb) Default Value 6Ah R/W Zone 1 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h 6Bh R/W Zone 2 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h 6Ch R/W Zone 3 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h Table 8.39 Absolute Limit vs. Register Setting ABSOLUTE LIMIT ABS LIMIT (DEC) ABS LIMIT (HEX) -127 °c-127 81h . . . . . . . . . -50 °c-50 CEh . . . . . . . . . 0 °c0 00h . . . . . . . . . Table 8.37 Temperature Limit vs. Register Setting (continued) LIMIT LIMIT (DEC) LIMIT (HEX) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |