| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TPA3002D2PHPR bảng dữ liệu(PDF) 30 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TPA3002D2PHPR bảng dữ liệu(HTML) 30 Page - Texas Instruments |
|
30 / 38 page ![]() TPA3002D2 SLOS402C − DECEMBER 2002 − REVISED JANUARY 2004 www.ti.com 30 20 21 22 23 24 25 4 6 8 10121416 Thermal Via Quantity (13 Mil Diameter) THERMAL RESISTANCE vs THERMAL VIA QUANTITY 2-LAYER PCB Figure 39. Thermal Resistance BASIC MEASUREMENT SYSTEM This application note focuses on methods that use the basic equipment listed below: D Audio analyzer or spectrum analyzer D Digital multimeter (DMM) D Oscilloscope D Twisted pair wires D Signal generator D Power resistor(s) D Linear regulated power supply D Filter components D EVM or other complete audio circuit Figure 40 shows the block diagrams of basic measurement systems for class-AB and class-D amplifiers. A sine wave is normally used as the input signal since it consists of the fundamental frequency only (no other harmonics are present). An analyzer is then connected to the APA output to measure the voltage output. The analyzer must be capable of measuring the entire audio bandwidth. A regulated dc power supply is used to reduce the noise and distortion injected into the APA through the power pins. A System Two audio measurement system (AP-II) (Reference 1) by Audio Precision includes the signal generator and analyzer in one package. The generator output and amplifier input must be ac-coupled. However, the EVMs already have the ac-coupling capacitors, (CIN), so no additional coupling is required. The generator output impedance should be low to avoid attenuating the test signal, and is important since the input resistance of APAs is not very high (about 10 k Ω). Conversely the analyzer-input impedance should be high. The output impedance, ROUT, of the APA is normally in the hundreds of milliohms and can be ignored for all but the power-related calculations. Figure 40(a) shows a class-AB amplifier system. They take an analog signal input and produce an analog signal output. These amplifier circuits can be directly connected to the AP-II or other analyzer input. This is not true of the class-D amplifier system shown in Figure 40(b), which requires low pass filters in most cases in order to measure the audio output waveforms. This is because it takes an analog input signal and converts it into a pulse-width modulated (PWM) output signal that is not accurately processed by some analyzers. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |