| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
CD2RMC bảng dữ liệu(PDF) 2 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
CD2RMC bảng dữ liệu(HTML) 2 Page - Greystone Energy Systems Inc. |
|
2 / 2 page ![]() PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-CD2RMCXXX-02 Greystone Energy Systems, Inc. 150 English Drive, Moncton, New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com WIRING INFORMATION TERMINAL FUNCTION SETPNT Resistance Output CO 2 Analog Output COM COMMON PWR Supply Voltage TEMP Resistance Output SWITCH Digital Output RELAY Digital Output PRODUCT CD2RMC Room Carbon Dioxide Sensor DISPLAY C V Concealed LCD (Not available if setpoint selected) Viewable LCD OPTIONAL TEMPERATURE SENSOR XX 02 05 06 07 08 12 13 14 20 24 59 None 100 Ω Platinum, IEC 751, 385 Alpha, thin film, 3-wire 1801 Ω NTC Thermistor, ±0.2°C 3000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 3, NTC Thermistor, ±0.2°C 2.252K Ω NTC Thermistor, ±0.2°C 1000 Ω Platinum, IEC 751, 385 Alpha, thin film 1000 Ω Nickel, Class B, DIN 43760 10,000 Ω Type 3, NTC Thermistor, ±0.2°C c/w 11,000 shunt resistor 20,000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 2, NTC Thermistor, ±0.2°C 10,000 Ω, 25°C, ±1%, B = 3435 ±1% (25/85) OPTIONAL RELAY X R None Adjustable Relay OPTIONAL OVERRIDE X S None Override OPTIONAL SETPOINT ADJUSTMENT XXX P00 P01 P02 None 0 to 10,000Ω 20,000 to 30,000Ω 2,000 to 3,000Ω ORDERING PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. NOTE: Additional setpoint values are available. Please contact Greystone. 5-YEAR CALIBRATION GUARANTEE Greystone offers a 5-year calibration guarantee on all its CD series wall and duct mount sensors used for CO 2 based ventilation control when operated in an environment that can utilize ASC software. If the sensor is found to be out of calibration more than 150 PPM as compared to a calibration gas or recently calibrated reference, Greystone will provide a free factory calibration of the sensor if returned to Greystone. This guarantee only applies if the sensor is operated in an environment where inside levels periodically drop to outside concentrations (i.e. during evenings or weekends when there is no occupancy) as is required by ASC software. ACCESSORIES CDD1-CALKIT-GS Calibration kit (Gas not included) for calibrating CD & CDD series CO 2 Transmitters. SETPNT CO2 COM PWR TEMP SWITCH RELAY MENU UP DOWN OVERRIDE CO2 SENSOR |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |