| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ADT7482ARMZ bảng dữ liệu(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADT7482ARMZ bảng dữ liệu(HTML) 21 Page - Analog Devices |
|
21 / 24 page ![]() ADT7482 Rev. 0 | Page 21 of 24 THERM2 LIMIT THERM LIMIT THERM2 1 3 2 4 TEMPERATURE THERM 90°C 80°C 70°C 60°C 50°C 40°C 30°C Figure 22. Operation of the THERM and THERM2 Interrupts 1. When the THERM2 limit is exceeded, the THERM2 signal asserts low. 2. If the temperature continues to increase and exceeds the THERM limit, the THERM output asserts low. 3. The THERM output de-asserts (goes high) when the temperature falls to THERM limit minus hysteresis. In Figure 22, there is no hysteresis value shown. 4. As the system cools further, and the temperature falls below the THERM2 limit, the THERM2 signal resets. Again, no hysteresis value is shown for THERM2. The temperature measurement could be either the local or the remote temperature measurement. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|