CSPT855 bảng dữ liệu(HTML) 4 Page - Renesas Technology Corp |
|
4 / 11 page ![]() 4 COMMERCIALANDINDUSTRIALTEMPERATURERANGES IDTCSPT855 2.5V PLL CLOCK DRIVER DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE Following Conditions Apply Unless Otherwise Specified: Commercial: TA = 0°C to +70°C; Industrial: TA = –40°C to +85°C Symbol Parameter Conditions Min. Typ.(1) Max. Unit VIK Input Voltage (All Inputs) VDDQ = 2.3V, II = -18mA — — – 1.2 V VOH HIGH-Level Output Voltage VDDQ = Min. to Max., IOH = -1mA VDDQ – 0.1 — — V VDDQ = 2.3V, IOH = -12mA 1.7 — — VOL LOW-Level Output Voltage VDDQ = Min. to Max., IOL = 1mA — — 0.1 V VDDQ = 2.3V, IOL = 12mA — — 0.6 IOH HIGH-Level Output Current VDDQ = 2.3V, VO = 1V – 18 – 32 — mA IOL LOW-Level Output Current VDDQ = 2.3V, VO = 1.2V 26 35 — mA VOD Output Voltage Swing Differentialoutputsareterminatedwith120 Ω 1.1 — VDDQ – 0.4 V VOX Output Differential Cross Voltage(2) Differentialoutputsareterminatedwith120 Ω VDDQ/2 – 0.2 VDDQ/2 VDDQ/2 + 0.2 V II InputCurrent VDDQ = 2.7V, VI = 0V to 2.7V — — ±10 μA IOZ High-ImpedanceStateOutputCurrent VDDQ = 2.7V, VO = VDDQ or GND — — ±10 μA IDD(PD) Power-Down Current on VDDQ and AVDD CLK and CLK = 0MHz, PWRDWN = LOW, — 100 200 μA Σ of IDD and AIDD IDD Dynamic Current on VDDQ CL = 14pF fO = 167MHz, Differential outputs terminated with 120 Ω — 150 180 mA CL = 0pF fO = 167MHz, Differential outputs terminated with 120 Ω — 130 160 AIDD Supply Current on AVDD fO = 167MHz — 8 10 mA CI InputCapacitance VDDQ = 2.5V, VI = VDDQ or GND 2 2.5 3 pF CO OutputCapacitance VDDQ = 2.5V, VI = VDDQ or GND 2.5 3 3.5 pF NOTES: 1. All typical values are at respective nominal VDDQ. 2. Differential cross-point voltage is expected to track variation of VDDQ and is the voltage at which the differential signals must be crossing. TIMING REQUIREMENTS Symbol Parameter Min. Max. Unit fCLK Operating Clock Frequency 60 220 MHz tDC Input Clock Duty Cycle 40 60 % tL Stabilization Time (PLL Mode)(1) —10 μs tL Stabilization Time (Bypass Mode)(2) —30 ns NOTES: 1. Recovery time required when the device goes from power-down mode into bypass mode (test mode with AVDD at GND). 2. Time required for the integrated PLL circuit to obtain phase lock of its feedback signal to its reference signal. For phase lock to be obtained, a fixed-frequency, fixed-phase reference signal must be present at CLK. Until phase lock is obtained, the specifications for propagation delay, skew, and jitter parameters given in the switching characteristics table are not applicable. This parameter does not apply for input modulation under SSC application. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |