3 / 13 page ![]() Data sheet W-Series WDK 2.5 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Creation date January 25, 2016 1:00:01 PM CET Catalogue status 15.01.2015 / We reserve the right to make technical changes. 3 Conductors for clamping (rated connection) Blade size 0.6 x 3.5 mm Clamping range, rated connection, max. 4 mm² Clamping range, rated connection, min. 0.05 mm² Clamping screw M 2.5 Connection direction on side Cross-section for connected conductor, finely stranded with wire-end ferrules and plastic collars DIN 46228/4, rated connection, min. 0.5 mm² Gauge to IEC 60947-1 A3 Number of connections 4 Stripping length 10 mm Tightening torque, max. 0.6 Nm Tightening torque, min. 0.4 Nm Torque level with DMS electric screwdriver 1 Type of connection Screw connection Wire connection cross section AWG, max. AWG 12 Wire connection cross section AWG, min. AWG 30 Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, max. 2.5 mm² Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, min. 0.5 mm² Wire connection cross section, finely stranded, max. 4 mm² Wire connection cross section, solid core max. rated connection 4 mm² Wire connection cross section, solid core, min. rated connection 0.5 mm² Wire connection cross section, stranded, rated connection, max. 4 mm² Wire connection cross section, stranded, rated connection, min. 1.5 mm² Wire connection cross-section, finely stranded with wire-end ferrules and plastic collars DIN 46228/4, rated connection, max. 2.5 mm² Wire connection cross-section, finely stranded, min. 0.5 mm² Dimensions TS 35 offset 35.5 mm PE rating data PEN function No Rating data Rated cross-section 2.5 mm² Rated voltage 400 V Rated current 24 A Current at maximum wires 32 A Standards IEC 60947-7-1 Volume resistance according to IEC 60947-7-x 2.66 mΩ Rated impulse withstand voltage 6 kV Pollution severity 3 UL rating data Certificate No. (UR) E60693 Conductor size Factory wiring max. (UR) 12 AWG Conductor size Factory wiring min. (UR) 22 AWG Conductor size Field wiring max. (UR) 12 AWG Conductor size Field wiring min. (UR) 22 AWG Current size B (UR) 20 A Current size C (UR) 20 A Voltage size B (UR) 300 V Voltage size C (UR) 300 V |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |