TSP-BCMU360 bảng dữ liệu(PDF) 2 Page - TRACO Electronic AG |
|
|
|||||||||||||||||||||||||||||
TSP-BCMU360 bảng dữ liệu(HTML) 2 Page - TRACO Electronic AG |
|
2 / 9 page ![]() http://www.tracopower.com Page 2 of 9 Industrial Power Supplies TSP Series 70–600 Watt Input Specifications Input voltage range TSP 070/090 85 – 264 VAC universal input other models: 85 – 132 / 187 – 264 VAC autoselect output current derating at operation below 100 VAC see graph B, page 4 Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time 230 VAC 20 ms 115 VAC 10 ms at full load, 20 ms at 66% load Inrush current 115 VAC 230 VAC TSP 070/090 < 12 A < 20 A TSP 140/180 < 13 A < 25 A TSP 360 < 36 A < 42 A TSP 600 < 25 A < 30 A Recommended circuit breaker, TSP 070/090/140/180 6.0 – 16.0 A characteristic B TSP 360 10.0 – 16.0 A TSP 600 16.0 – 25.0 A Efficiency 87 % typ. Output Specifications Output voltage adj. range 12 VDC models: 12 – 14 VDC 24 VDC models: 24 – 28 VDC 36 VDC model: 36 – 42 VDC 48 VDC models: 48 – 56 VDC At output voltage higher than nominal output voltage max. output current has to be reduced accordingly, in order not to exceed max. output power. Regulation – Input variation 0.5 % max. – Load variation (10–100 %) 0.5 % max. Ripple and Noise (20MHz bandwidth) 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Electronic short circuit protection current limitation at Imax. constant current, automatic recovery Output overvoltage protection 12 VDC models: 20 V 24 VDC models: 35 V 36 VDC model: 43 V 48 VDC models: 60 V Overload protection electronic overload protection Overtemperature protection switch off at overtemperature, automatic restart Power back immunity 12 VDC models: 16 V 24 VDC models: 35 V 36 VDC model: 48 V 48 VDC models: 63 V Status indicator dual color LED (green: DC ok, red: DC off) Power OK signal – trigger threshold: 12 VDC models: 9 – 11 V 24 VDC models: 18 – 22 V 36 VDC model: 27 – 34 V 48 VDC models: 36 – 46 V – active output signal: 12 VDC models: 11.0 V ±1.0 V (reference to –Vout) (20 mA max. for TSP 070, 40 mA max. for TSP 140) 24 VDC models: 22.0 V ±2.0V / 20 mA max. (10 mA max. for TSP 090, 20mA max. for others) 36 VDC model: 34.0 V ±2.0 V / 20 mA max. 48 VDC models: 44.0 V ±4.0 V / 15 mA max. – relay output DC OK = contact closed rated: 30 VDC/1.0 A for 12/24 VDC models rated: 30 VDC/2.0 A for 36 VDC model rated: 48 VDC/0.5 A for 48 VDC models |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |