| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
XRT75R06DIB bảng dữ liệu(PDF) 4 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRT75R06DIB bảng dữ liệu(HTML) 4 Page - Exar Corporation |
|
4 / 105 page ![]() XRT75R06D áç áç áç áç SIX CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCHRONIZER REV. 1.0.0 I TABLE OF CONTENTS GENERAL DESCRIPTION ................................................................................................. 1 APPLICATIONS .............................................................................................................................................. 1 Figure 1. Block Diagram of the XRT 75R06D ................................................................................................... 1 ORDERING INFORMATION ................................................................................................................... 1 FEATURES .................................................................................................................................................... 2 TRANSMIT INTERFACE CHARACTERISTICS ...................................................................................................... 2 RECEIVE INTERFACE CHARACTERISTICS ........................................................................................................ 2 Figure 2. XRT75R06D in BGA package (Bottom View) .................................................................................... 3 TABLE OF CONTENTS .................................................................................................................................... I PIN DESCRIPTIONS (BY FUNCTION) .............................................................................. 4 TRANSMIT INTERFACE ................................................................................................................................... 4 RECEIVE INTERFACE ..................................................................................................................................... 6 CLOCK INTERFACE ........................................................................................................................................ 8 CONTROL AND ALARM INTERFACE ....................................................................................................... 9 ANALOG POWER AND GROUND ................................................................................................................... 12 DIGITAL POWER AND GROUND ..................................................................................................................... 14 FUNCTIONAL DESCRIPTION ......................................................................................... 16 1.0 R3 Technology (reconfigurable, relayless redundancy) ............................................................... 16 1.1 NETWORK ARCHITECTURE ................................................................................................................................ 16 Figure 3. Network Redundancy Architecture ................................................................................................. 16 2.0 clock Synthesizer ............................................................................................................................. 17 2.1 CLOCK DISTRIBUTION ....................................................................................................................................... 17 Figure 5. Clock Distribution Congifured in E3 Mode Without Using SFM ....................................................... 17 Figure 4. Simplified Block Diagram of the Input Clock Circuitry Driving the Microprocessor .......................... 17 3.0 The Receiver Section ....................................................................................................................... 18 Figure 6. Receive Path Block Diagram ........................................................................................................... 18 3.1 RECEIVE LINE INTERFACE ................................................................................................................................. 18 Figure 7. Receive Line InterfaceConnection ................................................................................................... 18 3.2 ADAPTIVE GAIN CONTROL (AGC) ..................................................................................................................... 19 3.3 RECEIVE EQUALIZER ........................................................................................................................................ 19 Figure 8. ACG/Equalizer Block Diagram ......................................................................................................... 19 3.3.1 Recommendations for Equalizer Settings ....................................................................................... 19 3.4 CLOCK AND DATA RECOVERY .......................................................................................................................... 19 3.4.1 Data/Clock Recovery Mode ............................................................................................................... 19 3.4.2 Training Mode ..................................................................................................................................... 19 3.5 LOS (LOSS OF SIGNAL) DETECTOR .................................................................................................................. 20 3.5.1 DS3/STS-1 LOS Condition ................................................................................................................. 20 3.5.2 Disabling ALOS/DLOS Detection ...................................................................................................... 20 TABLE 1: THE ALOS (ANALOG LOS) DECLARATION AND CLEARANCE THRESHOLDS FOR A GIVEN SETTING OF LOSTHR AND REQEN (DS3 AND STS-1 APPLICATIONS) ................................................................... 20 3.5.3 E3 LOS Condition: ............................................................................................................................. 21 Figure 9. Loss Of Signal Definition for E3 as per ITU-T G.775 ....................................................................... 21 Figure 10. Loss of Signal Definition for E3 as per ITU-T G.775. ..................................................................... 21 3.5.4 Interference Tolerance ....................................................................................................................... 22 Figure 11. Interference Margin Test Set up for DS3/STS-1 ............................................................................ 22 Figure 12. Interference Margin Test Set up for E3. ......................................................................................... 22 TABLE 2: INTERFERENCE MARGIN TEST RESULTS .............................................................................................. 23 3.5.5 Muting the Recovered Data with LOS condition: ............................................................................ 24 3.6 B3ZS/HDB3 DECODER .................................................................................................................................... 24 Figure 13. Receiver Data output and code violation timing ............................................................................ 24 4.0 The Transmitter Section .................................................................................................................. 25 Figure 14. Transmit Path Block Diagram ........................................................................................................ 25 4.1 TRANSMIT DIGITAL INPUT INTERFACE ................................................................................................................ 25 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |