| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TBP bảng dữ liệu(PDF) 2 Page - DIWELL Electronics Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
TBP bảng dữ liệu(HTML) 2 Page - DIWELL Electronics Co., Ltd. |
|
2 / 5 page ![]() TB(P) Series Specification Non-contact Infrared Temperature Sensor Page 2 of 5 1.0.0 Typical application schematics - TB series (External pull-up resistor required) - TBP series(No external resistor required. 1.5㏀ pull-up resistor applied) SMBus compatible 2-wire protocol - The TB(P) series supports a 2 wire serial protocol. And the TB(P) only supports two protocols on standard SMBus interface. Supported commands are: Read Word, Write Word Functional description The TB(P) sensor module can only be used as a slave device. Maximum number of devices on one bus is 127, higher pull-up currents are recommended for higher number of devices, faster bus data transfer rates, and increased reactive loading of the bus. If the access to the device is a read operation it will respond with 16 data bits and 8 bit PEC only if its own slave address. Bus Protocol The TB(P) sensors are preset to address 0x3A by default. 1 7 1 1 8 1 1 S Slave Address Wr A Data Byte A P S Start Condition Sr Repeated Start Condition Rd Read (bit value of 1) Wr Write (bit value of 0) A Acknowledge(this bit can be 0 for ACK and 1 for Nack) S Stop condition PEC Packet Error Code(*) Master-to-Slave Slave-to-Master * The PEC calculation includes all bits except the START, REPEATED START, STOP, ACK, and NACK bits. The PEC is a CRC-8 with polynomial X8+X2+X1+1. The MSB(Most Significant Bit) of every byte is transferred first. Packet Error Code(PEC) Calculation A packet error checking mechanism according to SMBus specification version 1.1 is implemented. The packet error checking of SMBus devices uses an 8-bit cyclic redundancy check (CRC-8) to calculate the PEC. The polynomial used is C(x)= 100000111 (= x8 + x2 + x + 1) . The PEC calculation includes all bytes in the transmission, including address, command and data. It does not include ACK, NACK, START, STOP bits. Refer to the Arduino example code for detailed PEC calculation. Read Word 1 7 1 1 8 1 1 7 1 1 S Slave Address Wr A Command Address(*) A Sr Slave Address Rd A 8 1 8 1 8 1 1 ∙∙∙ Data Byte Low A Data Byte High A PEC A P * Command Address configures Register Name Command Address R/W Ambient 0x06 R Object 0x07 R Emissivity correction coefficient 0x24 R/W Slave Address 0x2E R/W Any device will respond to address zero The MSB of the temperature data is an error flag (active high). Please note after POR additional delay is needed before first reading can be started. - Read operation flow diagram Oscilloscope waveform image 1. (Read Object) Oscilloscope waveform image 2. (Read Ambient) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |