| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SCD42-D-R2 bảng dữ liệu(PDF) 4 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SCD42-D-R2 bảng dữ liệu(HTML) 4 Page - Sensirion AG Switzerland |
|
4 / 21 page ![]() www.sensirion.com Version 1 – March 2022 4/21 2 Specifications 2.1 Electrical Specifications Parameter Symbol Conditions Min. Typical Max. Units Supply voltage DC6 VDD 2.4 3.3 5.5 V Voltage ripple peak to peak VRPP Frequency ≥ 1 kHz 30 mV Supply voltage variation7 VVar Frequency < 1 kHz ±5 mV Peak supply current8 Ipeak VDD = 3.3 V 175 205 mA VDD = 5 V 115 137 mA Average supply current for periodic measurement IDD VDD = 3.3 V 15 18 mA VDD = 5 V 11 13 mA Input high level voltage VIH 0.65 x VDD VDD - Input low level voltage VIL 0.3 x VDD - Output low level voltage VOL 3 mA sink current 0.66 V Table 4 SCD42 electrical specifications 2.2 Absolute Maximum Ratings Stress levels beyond those listed in Table 5 may cause permanent damage to the device. Exposure to minimum/maximum rating conditions for extended periods may affect sensor performance and reliability of the device. Parameter Conditions Value Temperature operating conditions 0 – 50°C Humidity operating conditions9 Non-condensing 0 – 95 %RH MSL Level10 1 DC supply voltage - 0.3 V – 6.0 V Max voltage on pins SDA, SCL, GND – 0.3 V to VDD+0.3 V Input current on pins SDA, SCL, GND - 280 mA to 100 mA Short term storage temperature11 - 40°C – 70°C Recommended storage temperature 10 °C – 30 °C ESD HBM 2 kV ESD CDM 500 V Maintenance Interval Maintenance free when ASC field- calibration algorithm12 is used. None Sensor lifetime13 Typical operating conditions > 10 years Table 5: SCD42 operation conditions, lifetime and maximum ratings 6 Do not change supply voltage during operation 7 Accuracy can be impaired by excess supply voltage variation caused by external load or temperature variations 8 Power supply should be designed with respect to peak current. 9 Accuracy can be reduced at relative humidity levels lower than 10 %. 10 Exceeding MSL 1 storage conditions (30 °C, 85 % RH max.) prior to sensor assembly can lead to degraded sensor performance or sensor failure in the reflow soldering process. 11 Short term storage refers to temporary conditions during e.g. transport. 12 For proper function of ASC field-calibration algorithm the SCD42 has to be exposed to clean air with 400 ppm CO2 concentration regularly. 13 Sensor tested over simulated lifetime of > 10 years for indoor environment mission profile |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |