Back Button HT0610 Datasheet HTML 14Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 15Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 16Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 17Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 18Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 19Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 20Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 21Page - Holtek Semiconductor Inc HT0610 Datasheet HTML 22Page - Holtek Semiconductor Inc  
Zoom Inzoom in Zoom Outzoom out
 18 / 22 page
background image
Command Required for Display Mode Setup
Display Mode
Command Required
Display Mode
Set external/internal oscillator*
Set oscillator enable*
Set display on*
Static Icon Display
Set external/internal oscillator*
Set oscillator enable*
Set static Icon control signal*
Standby Mode 1
Set display off*
Set oscillator disable*
Standby Mode 2
Set external oscillator*
Set static Icon control signal*
Set display off*
Set oscillator enable*
Standby Mode 3
Set internal oscillator*
Set static Icon control signal*
Set display off*
Set oscillator enable*
Other related command with display mode: set duty cycle, set column mapping, set row mapping, set vertical scroll
value.
Command Related to Internal DC/DC Converter
Set oscillator disable/enable, set internal regulator on/off, set duty cycle, set temperature coefficient, set internal con-
trast control on/off, increase contrast level, set internal voltage divider on/off, set bias ratio, set display on/off, set inter-
nal/external oscillator, set contrast level, set voltage doubler/tripler, set 33 mux display mode, set Icon display mode.
* You do not need to resend the command again if it is set previously.
Command Required for R/W Actions on RAM
R/W Actions on RAM
Command Required
Read data from BGDRAM
Write data to BGDRAM
Set BGDRAM page address*
Set BGDRAM column address*
Read/write data
Save or restore BGDRAM column address
Save or restore BGDRAM column address
Increase BGDRAM address by one
Dummy read data
Master clear BGDRAM
Master clear BGDRAM
Dummy write data
* You do not need to resend the command again if it is set previously.
HT0610
Rev. 1.00
18
February 24, 2004



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com