| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
HT48CU80 bảng dữ liệu(PDF) 26 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT48CU80 bảng dữ liệu(HTML) 26 Page - Holtek Semiconductor Inc |
|
26 / 54 page ![]() HT48RU80/HT48CU80 Rev. 1.00 26 April 12, 2006 ¨ RIE This bit enables or disables the receiver interrupt. If this bit is equal to ²1² when the receiver overrun OERR flag or receive data available RXIF flag is set, the UART interrupt request flag will be set. If this bit is equal to ²0² the UART interrupt will not be influenced by the condition of the OERR or RXIF flags. ¨ WAKE This bit enables or disables the receiver wake-up function. If this bit is equal to ²1² and if the MCU is in the Power Down Mode, a low going edge on the RX input pin will wake-up the device. If this bit is equal to ²0² and if the MCU is in the Power Down Mode, any edge transitions on the RX pin will not wake-up the device. ¨ ADDEN The ADDEN bit is the address detect mode bit. When this bit is ²1² the address detect mode is en- abled. When this occurs, if the 8th bit, which corre- sponds to RX7 if BNO=0, or the 9th bit, which corresponds to RX8 if BNO=1, has a value of ²1² then the received word will be identified as an ad- dress, rather than data. If the corresponding inter- rupt is enabled, an interrupt request will be generated each time the received word has the ad- dress bit set, which is the 8 or 9 bit depending on the value of BNO. If the address bit is ²0² an interrupt will not be generated, and the received data will be discarded. ¨ BRGH The BRGH bit selects the high or low speed mode of the Baud Rate Generator. This bit, together with the value placed in the BRG register, controls the Baud Rate of the UART. If this bit is equal to ²1² the high speed mode is selected. If the bit is equal to ²0² the low speed mode is selected. ¨ RXEN The RXEN bit is the Receiver Enable Bit. When this bit is equal to ²0² the receiver will be disabled with any pending data receptions being aborted. In addi- tion the buffer will be reset. In this situation the RX pin can be used as a general purpose I/O pin. If the RXEN bit is equal to ²1² the receiver will be enabled and if the UARTEN bit is equal to ²1² the RX pin will be controlled by the UART. Clearing the RXEN bit during a transmission will cause the data reception to be aborted and will reset the receiver. If this oc- curs, the RX pin can be used as a general purpose I/O pin. ¨ TXEN The TXEN bit is the Transmitter Enable Bit. When this bit is equal to ²0² the transmitter will be disabled with any pending transmissions being aborted. In addition the buffer will be reset. In this situation the TX pin can be used as a general purpose I/O pin. If the TXEN bit is equal to ²1² the transmitter will be enabled and if the UARTEN bit is equal to ²1² the TX pin will be controlled by the UART. Clearing the TXEN bit during a transmission will cause the trans- mission to be aborted and will reset the transmitter. If this occurs, the TX pin can be used as a general purpose I/O pin. · Baud rate generator To setup the speed of the serial data communication, the UART function contains its own dedicated baud rate generator. The baud rate is controlled by its own internal free running 8-bit timer, the period of which is determined by two factors. The first of these is the value placed in the BRG register and the second is the value of the BRGH bit within the UCR2 control regis- ter. The BRGH bit decides, if the baud rate generator is to be used in a high speed mode or low speed mode, which in turn determines the formula that is used to calculate the baud rate. The value in the BRG register determines the division factor, N, which is used in the following baud rate calculation formula. Note that N is the decimal value placed in the BRG register and has a range of between 0 and 255. UCR2 BRGH Bit 0 1 Baud Rate f [64 (N + 1)] SYS f [16 (N + 1)] SYS By programming the BRGH bit which allows selection of the related formula and programming the required value in the BRG register, the required baud rate can be setup. Note that because the actual baud rate is determined using a discrete value, N, placed in the BRG register, there will be an error associated be- tween the actual and requested value. The following example shows how the BRG register value N and the error value can be calculated. Calculating the register and error values For a clock frequency of 8MHz, and with BRGH set to ²0² determine the BRG register value N, the actual baud rate and the error value for a desired baud rate of 9600. From the above table the desired baud rate BR = f [64 (N + 1)] SYS Re-arranging this equation gives N = f (BRx64) SYS - 1 Giving a value for N = 8000000 9600 64 () x - 1 = 12.0208 To obtain the closest value, a decimal value of 12 should be placed into the BRG register. This gives an actual or calculated baud rate value of BR = 8000000 [64(12 + 1)] = 9615 Therefore the error is equal to = 0.16% 9 6 1 5 9 6 0 0 9 6 0 0 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |