3 / 12 page ![]() EC-E... 103906_en_01 PHOENIX CONTACT 3 3 Technical data NOTE: Data apply where T A = 25°C and UB = 24 V DC. Operating data Nominal voltage U B 24 V DC (18 V DC ... 32 V DC) Nominal current I N Depending on product version selected: Fixed current strengths: 0.5 A, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A Closed-circuit current I 0 When ON: Typically 20 mA ... 30 mA, depending on signal output Shutdown Shutdown times Refer to the time/current characteristic curve (see page 8) Typical behavior 3 s where I load > 1.1 x IN 100 ms ... 3 s where I load > 1.8 x IN (or 1.5 x IN/1.3 x IN) EC-E4: Pin 11/12 Individual signaling (N/C contact) EC-E1: Pin 13/14 Individual signaling (N/O contact) EC-E: SF 23, RE 22 RE reset input, SF status output Status indicators Operating state signaling – Multi-color LED – SF status output (option) – Floating signal contact (F alarm output) (option) – On/off setting for switch S1 Multi-color LED Green = Device switched on (S1 = ON) or load circuit/Power MOSFET forced to trip Orange = Overload or short circuit leading to electronic shutdown Red = Device shut down electronically, load circuit/Power MOSFET switched off, undervoltage (U B < 8 V) or after switch-on up to end of switch-on delay time OFF: Manually switched off (S1 = OFF) or device voltage is disconnected Load circuit Load output Power MOSFET switching output (positive switching) Overload shutdown (OL) Typically 1.1 x I N (1.05 ... 1.35 x IN) Short-circuit current I K Active current limitation (see page 5) Temperature shutdown Internal temperature monitoring with electronic shutdown Undervoltage monitoring for load output after each switch-on procedure With hysteresis, no reset required: Load "OFF" at U B < 8 V Switch-on delay t Start Typically 0.5 s after reset and after U B applied Load circuit shutdown Electronic shutdown after overload/short circuit Free running circuit External free-wheeling diode recommended for inductive load Parallel connection of multiple load outputs Not permitted F alarm output, signal contact (for EC-E1 and EC-E4 only) Electrical data Floating signal contact 30 V DC/0.5 A maximum, 10 V/10 mA minimum Normal state, LED lights up green U B is present, switch S1 is set to ON, and no overloads or short circuits occur OFF state, LED off – Device switched off (switch S1 set to OFF) – Operating voltage U B is not present |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |