| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PLD36SZ bảng dữ liệu(PDF) 2 Page - ETA-USA |
|
|
|||||||||||||||||||||||||||||
PLD36SZ bảng dữ liệu(HTML) 2 Page - ETA-USA |
|
2 / 4 page ![]() ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com PLD**SZ Specification Specifications<AC/DC> PLD**SZ 120WATTS(Peak 180W)/SINGLE Output Voltage [V] 12 24 36 Output Current [A] 9(Peak 15.0) 5.0(Peak 7.5) 3.4(Peak 5.0) Voltage Adjust Range Ripple and Noise [mVp-p](maximum) *3 220 340 460 Regulation Statistic Line Regulation [mV](maximum) 96 192 288 Statistic Load Regulation [mV](maximum) 108 216 324 Temperature Coefficient *4 Drift[mV](maximum) *5 75 135 195 Dynamic Load Regulation [mV](typical) *6 360 720 1080 Recovery Time *6 Rise up time Hold up time 15.5 7.5 5.0 13.2 26.4 39.6 Remote Sense Parallel/series Operation Operating Temperature *7 Operating Humidity Storage Temperature Storage Humidity Shock Cooling ? Leakage Current ? Line Conducted Noise ? Safety Weight (typical) ? MTBF [H] ? Sw itching Frequency[kHz](typical) 490g/enclosed type:600g 620,000 80 294m/s2 Convection 1mA(maximum) at 25℃,rated input/output and rated input frequency Built to meet FCC Part15-B Class B Isolation Resistance Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 500mS(maximum) at 25℃ and rated input/output 20mS(minimum) at 25℃ and rated input/output Functions Overcurrent Protection [A](minimum) Current Limiting w ith automatic recovery 0.03%/℃ 0.5mS(typical) Model PLD12SZ PLD24SZ PLD36SZ Output Characteristic +/- 10% of Rated Output Voltage(at no load w ithin the input range) Overvoltage Protection ≧110% of Rated Output Voltage[V] Output shutdow n(to reset,leave 1minute after shut-off) not available not available Environmental 0 to +50℃ 85%RH(non-condensing) -40 to +85℃ 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC2,500V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC500V for 1minute *5 for 7hour period after 1hour w arm-up at 25℃ and rated input/output *6 w hen output current changed from 25% and 75% of rated output current rapidly at AC100/200V input Conditions: *1 at cold start *2 at AC100/200V input and at 25℃ *3 measured by a bayonet probe at output connector at 0 to 100MHz bandw idth *4 at -5 to +50℃ |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |