| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PTC305CSERIES bảng dữ liệu(PDF) 5 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
PTC305CSERIES bảng dữ liệu(HTML) 5 Page - Vishay Siliconix |
|
5 / 8 page ![]() PTC305C Series www.vishay.com Vishay Cera-Mite Revision: 11-Sep-15 5 Document Number: 23086 For technical questions, contact: ceramitesupport@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PTC SELECTION • Choosing the best PTC for an application is a simple matter. See Table 4 and Table 2. Vishay Cera-Mite PTCs are available in three case sizes (A, B, and C) • Table 4 indicates the correct case size for the application. Table 2 shows how to choose the correct resistance value • Using a device too small or resistance too high will give inadequate starting performance. An oversize device will not harm the motor, but may not be optimum with regards to acceleration dynamics, or power dissipation • The PTC is generally self protecting when applied within the voltage and current ratings • All PTC305C Series starters and accessories are RoHS compliant Table 4 Notes (1) Preferred values. (2) Part number is stamped on the device for UL recognition. The customer part number can also include 1 or 3 character alpha-numeric suffix to designate specific customer marking and accessory furnished. The suffix is not marked on the part. Certified outline drawing and complete part number will be furnished on request for specific applications.(Example: PTC305C19K01.) Mounting brackets and other accessories are to be ordered separately. (3) RDYN is nominal resistance equal to U/I when 230 V, 50 Hz/60 Hz is applied (see Fig T-7). This resistance determines current and maximum starting torque at the moment of application of voltage to the motor and can be measured with an oscilloscope. For receiving inspection or routine trouble shooting, the DC resistance at 25 °C (R25) as measured with an ohmmeter is approximately 50 % greater. For example: PTC305C20 measured with an ohmmeter would be 35 ± 30 % tolerance. (4) Resistance values are duplicated in several case sizes (i.e.: PTC305C20, C12, and C1) to provide longer switch time (t) and higher current ratings (see Fig. T-7). Larger parts may be needed for more difficult starting conditions (voltage or temperature) or may be used for accelerating fans against back pressure. (5) Maximum current in the PTC is determined by Motor auxiliary winding impedance is usually small compared to PTC resistance, and does not materially affect PTC current. Current in PTC is a percentage of the full motor inrush (locked rotor) current; usually 30 % to 50 % (see Fig T-5). (6) In application, the maximum voltage is the voltage that appears across the run capacitor at rated speed, high line, light load. This is not the applied line voltage (see Fig T-6). THESE DEVICES ARE INTENDED FOR APPLICATION ON 240 VOLT LINES OR SYSTEMS WITH MAXIMUM LINE VOLTAGE UP TO 265 V. The PTC305C20, 21 and 22 are also used on 120 V systems where the motor is designed to use same run capacitor and PTC as equivalent 230 V compressor. (7) This is the power used to keep the PTC switched in a high impedance state under full load running conditions at typical ambient temperature. (8) BTU and horsepower ranges are for reference only. PTC may be applied outside those ranges as long as maximum voltage and maximum current are not exceeded. Scroll and rotary compressors may require less starting assistance allowing use of smaller devices. PTC MOTOR START SELECTION CHART VISHAY CERA-MITE PART NUMBER (2) CASE STYLE (2) RESISTANCE ( ) (3) SWITCH TIME (4) (t) s AT 230 V CURRENT RATING (5) (ARMS) MAX. VOLTAGE RATING (6) (VRMS) AVG. POWER DISSIPATION (7) (W) COMPRESSOR RANGE (8) RDYN ± 20 % R25 ± 30 % BTU (000) HP PTC305C20 (1) C 25 35 0.25 10 410 3.5 10 to 28 0.75 to 2.0 PTC305C21 C 35 50 0.35 8 410 3.5 8 to 18 0.5 to 1.5 PTC305C22 (1) C 50 75 0.50 6 410 3.5 5 to 12 0.25 to 1.0 PTC305C19 (1) B 20 30 0.50 18 500 7 20 to 50 1.5 to 4.0 PTC305C12 (1) B 25 40 0.60 15 500 7 18 to 42 1.5 to 3.5 PTC305C2 B 50 85 1.00 12 500 7 10 to 25 1.0 to 2.5 PTC305C9 (1) A 10 15 0.50 36 500 9 28 to 68 3.0 to 7.0 PTC305C11 A 12.5 20 0.60 30 500 9 28 to 62 3.0 to 6.0 PTC305C1 (1) A 25 42.5 1.00 24 500 9 14 to 36 1.5 to 3.5 UL File E97640 Maximum Line Voltage Minimum R DYN ------------------------------------------------------------- |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |