| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
71M6532D/F bảng dữ liệu(PDF) 90 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
71M6532D/F bảng dữ liệu(HTML) 90 Page - Maxim Integrated Products |
|
90 / 121 page ![]() Data Sheet 71M6531D/F-71M6532D/F FDS 6531/6532 005 90 Rev 2 Table 57: CESTATUS (CE RAM 0x80) Bit Definitions CESTATUS [bit] Name Description 31:29 Not Used These unused bits will always be zero. 28 F0 F0 is a square wave at the exact fundamental frequency for the phase selected with the FREQSELn bits in CECONFIG. 27 Reserved 26 SAG_B Normally zero. Becomes one when VB remains below SAG_THR for SAG_CNT samples. Will not return to zero until VB rises above SAG_THR. 25 SAG_A Normally zero. Becomes one when VA remains below SAG_THR for SAG_CNT samples. Will not return to zero until VA rises above SAG_THR. 24:0 Not Used These unused bits will always be zero. The CE is initialized and its functions are controlled by the MPU using CECONFIG. This register contains in packed form SAG_CNT, FREQSEL, EXT_PULSE, I0_SHUNT, I1_SHUNT, PULSE_SLOW and PULSE_FAST. The CECONFIG bit definitions are given in Table 58. CE Address Name Data Description 0x20 CECONFIG 0x5020 See description of the CECONFIG bits in Table 58. IA_SHUNT and/or IB_SHUNT can configure their respective current inputs to accept shunt resistor sensors. In this case the CE provides an additional gain of 8 to the selected current input. WRATE may need to be adjusted based on the values of IA_SHUNT and IB_SHUNT. Whenever IA_SHUNT or IB_SHUNT are set to 1, In_8 (in the equation for Kh) is assigned a value of 8. The CE pulse generator can be controlled by either the MPU (external) or CE (internal) variables. Control is by the MPU if EXT_PULSE = 1. In this case, the MPU controls the pulse rate by placing values into APULSEW, APULSER, APULSE2 and APULSE3. By setting EXT_PULSE = 0, the CE controls the pulse rate based on W0SUM_X and VAR0SUM_X (EQU[2:0] = 0) or WSUM_X (EQU[2:0] = 2). If EXT_PULSE = 0 and EQU[2:0] = 2, the pulse inputs are W0SUM_X + W1SUM_X and VAR0SUM_X + VAR1SUM_X. In this case, creep cannot be controlled since creep is an MPU function. If EXT_PULSE = 0 and EQU[2:0] = 0, the pulse inputs are W0SUM_X if I0SQSUM_X > I1SQSUM_X and W1SUM_X, if I1SQSUM_X > I0SQSUM_X. The 71M6531 Demo Code creep function halts both internal and external pulse generation. The EXT_TEMP bit controls the temperature compensation mode: • When EXT_TEMP = 0 (internal compensation), the CE will control the gain using GAIN_ADJ (see Table 60) based on PPMC, PPMC2 and TEMP_X, the difference between die temperature and the reference / calibration temperature TEMP_NOM. Since PPMC and PPMC2 reflect the typical behavior of the reference voltage over temperature, the internal temperature compensation eliminates the effects of temperature-related errors of VREF only. • When EXT_TEMP = 1 (external compensation), the MPU is allowed to control the CE gain using GAIN_ADJ, based on any algorithm implemented in MPU code. The FREQSEL1 and FREQSEL0 bits select the phase used to control the CE-internal PLL. CE accuracy depends on the channel selected by the FREQSEL1 and FREQSEL0 bits receiving a clean voltage signal. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |