| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
VGS-200B bảng dữ liệu(PDF) 2 Page - CUI INC |
|
|
|||||||||||||||||||||||||||||
VGS-200B bảng dữ liệu(HTML) 2 Page - CUI INC |
|
2 / 5 page ![]() cui.com date 06/10/2021 │ page 2 of 5 CUI Inc │ SERIES: VGS-200B │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage via input selector switch1 90 180 115 230 132 264 Vac Vac frequency 47 63 Hz current at 115 Vac, full load at 230 Vac, full load 4 2.5 A A inrush current at 230 Vac, cold start, full load 60 A leakage current at 240 Vac 2 mA no load power consumption at 230 Vac 0.75 W Notes: 1. Input selector must be set to match input voltage or damage could occur. OUTPUT parameter conditions/description min typ max units line regulation ±0.5 % load regulation 12 Vdc output model all other models ±1 ±0.5 % % adjustability built in trim pot ±10 % start-up time at 115/230 Vac, full load 1.5 s rise time at 115/230 Vac, full load 30 ms hold-up time at 115 Vac, full load at 230 Vac, full load 12 16 ms ms switching frequency 65 kHz PROTECTIONS parameter conditions/description min typ max units over voltage protection output shutdown, auto recovery 115 150 % over current protection output shutdown, auto recovery 105 150 % short circuit protection output shutdown, auto recovery over temperture protection output shutdown, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute, 10 mA input to ground for 1 minute, 10 mA output to ground for 1 minute, 10 mA 1,500 1,500 500 Vac Vac Vac isolation resistance input to output at 500 Vdc input to ground at 500 Vdc output to ground 500 Vdc 100 100 100 MΩ MΩ MΩ safety approvals certified to 62368: EN certified to 60950: IEC/UL safety class class I conducted emissions EN 55032:2015, Class A radiated emissions EN 55032:2015, Class A voltage fluctuation and flicker EN 61000-3-3:2013, Class A ESD immunity IEC 61000-4-2, air: ±8 kV; contact: ±4 kV, Class A radiated field immunity IEC 61000-4-3, 3 V/m, Class A electrical fast transient immunity IEC 61000-4-4, Ac power port: 1 kV; signal & telecommunication ports: 0.5 kV, Class B Notes: 2. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. Additional Resources: Product Page | 3D Model |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |