công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

OPA2188 bảng dữ liệu(PDF) 24 Page - Texas Instruments

Click here to check the latest version.
tên linh kiện OPA2188
Giải thích chi tiết về linh kiện  OPAx182 36-V, 5-MHz, Low-Noise, Zero-Drift, MUX-Friendly, Precision Op Amps
PDF  43 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  TI [Texas Instruments]
Trang chủ  http://www.ti.com
Logo TI - Texas Instruments

OPA2188 bảng dữ liệu(HTML) 24 Page - Texas Instruments

Back Button OPA2188 Datasheet HTML 20Page - Texas Instruments OPA2188 Datasheet HTML 21Page - Texas Instruments OPA2188 Datasheet HTML 22Page - Texas Instruments OPA2188 Datasheet HTML 23Page - Texas Instruments OPA2188 Datasheet HTML 24Page - Texas Instruments OPA2188 Datasheet HTML 25Page - Texas Instruments OPA2188 Datasheet HTML 26Page - Texas Instruments OPA2188 Datasheet HTML 27Page - Texas Instruments OPA2188 Datasheet HTML 28Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 43 page
background image
9.2.1.2 Detailed Design Procedure
The bridge sensor signal flow model is shown in Figure 9-2.
Figure 9-2. Bridge Sensor Signal Flow Model
The bridge sensor is modeled as a multiplier, with inputs from an excitation voltage and pressure sensor
producing an output voltage given in Equation 1:
bridge
exc
exc
p
V
(P,V
)
V
K (P)
u
(1)
Kp is the sensitivity of the bridge sensor, and is usually specified in mV/V. P represents the pressure relative to
the range of the sensor, normalized to a scale from 0 to 1. Solving this equation with the variables given in the
signal flow model and solving for Vout results in Equation 2:
OS
ref
p
out
lin
p
V
V
G K (P)
V
(P)
1 G K
K (P)
u
u
u
u
(2)
This equation has three variables, VOS, G and Klin, that require three equations to solve. To solve these
equations. values of Kp at no load, midscale and full load conditions are needed for the sensor. With these
values, the system can be linearized.
With known values for Kp, Klin is calculated as shown in Equation 3:
v
ref
lin
out _ high
out _ low
v
out _ high
out _ low
4 B
V
K
(V
V
) 2 B
(V
V
)
u
u
u
u
(3)
In this equation, Bv represents the bridge nonlinearity, which is calculated as shown in Equation 4:
p
p
p
v
p
p
K (1) K (0)
K (0.5)
2
B
K (1) K (0)
(4)
Bv is solved based on the sensor specifications, and the equation is then used to solve for Klin. Next, the system
gain is calculated using Equation 5 and Equation 6.
OS
ref
p
out _ high
lin
p
V
V
G K (1)
V
1 G K
K (1)
u
u
u
u
(5)
OS
ref
p
out _ high
lin
p
V
V
G K (0)
V
1 G K
K (0)
u
u
u
u
(6)
OPA182, OPA2182, OPA4182
SBOS936D – DECEMBER 2019 – REVISED DECEMBER 2021
www.ti.com
24
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: OPA182 OPA2182 OPA4182



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com