| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
4FFSTC15 bảng dữ liệu(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
4FFSTC15 bảng dữ liệu(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 4 page ![]() Concrete FLOOR STRUCTURE 2 IMPORTANT! The above maximum copper cross sectional area values are for each individual power and communication compartment. DO NOT add values together for any one compartment. NOTE: Use above values for solid or stranded conductors. Size Solid #24 .00032 sq. in. [.206mm2] #22 .00050 sq. in. [.322mm2] #14 .00323 sq. in. [2.083mm2] #12 .00512 sq. in. [3.303mm2] #10 .00815 sq. in. [5.258mm2] #8 .01296 sq. in. [8.361mm2] Copper Cross Sectional Area of Commonly Used Conductors CAUTION: These devices meet all UL scrub water requirements, but are not suitable for wet or damp locations, or other areas subject to saturation with water or other liquids such as commercial kitchens. Concrete Thickness Min/Max: 1-HOUR RATED FLOOR – 2 1/4" [57mm] minimum over top of deck (or 3" [76mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm]. 2-HOUR RATED FLOOR – 3 1/4" [83mm] minimum over top of deck (or 4" [102mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm]. 4FFATC Furniture Feed Style Poke-Thru Device Specifications * The above maximum copper fill values are the maximum amount of copper to maintain fire classification and are for each individual power and communication compartments. Do not add values together for any one compartment. 4FFATC Series Minimum: 4" [102mm] Maximum: 4 1/8" [105mm] 1, 1 1/2 & 2 Hours 2 Gangs One (1) 3/4" & one (1) 1 1/2" trade size Screw Plug Openings (16) #12 AWG or (10) #10 AWG .08192 Sq. in. [52.851mm2] (18) Cat 6/Channel .072 Sq. in. [46.45mm2] 8 1/4" [210mm] Powder Coated Colors: Black, Brass, Gray, Bronze, Nickel Brushed Aluminum One (1) 3/4" & one (1) 1 1/2" trade size Conduit Minimum: 1/8" [3.2mm] Maximum: 3/4" [19.1mm] 4" Diameter Hole POKE-THRU SERIES HOLE SIZE UL FIRE CLASSIFICATION CAPACITY POWER* COMMUNICATIONS* COVER SIZE COVER COLORS CONDUIT/STEM DIAMETER FLOOR COVERING THICKNESS TopGuard™ UL SCRUBWATER PROTECTION Die-Cast COVER CONSTRUCTION NOTE: The material that is used in Wiremold poke- thru devices is not listed under the directory for Fire Stopping Material because the poke- thru device is UL Classified as “Outlet Boxes and Fittings Classified For Fire Resistance (CEYY)”. The pass/fail criteria comes from UL263. The pass criteria is that the poke-thru unit cannot exceed 325° F. above ambient before the concrete slab (or deck) reaches this same temperature. Some poke-thru devices are tested for 2 hours while others are tested for 4 hours. The intumescent material has never been tested as a fire- stopping material as a stand-alone device. This material is designed to work as a unit with the entire poke-thru device. Scrub Water Gasket Trim Flange for Carpet or Tile Concrete Slab 1 1/2" Trade Size EMT Conduit Retaining Flange 3/4" Trade Size EMT Conduit Carpet, Tile & Wood FLOOR SURFACE |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |