13 / 58 page ![]() 2011-2021 Microchip Technology Inc. DS20002275C-page 13 RE46C180 3.8 End-of-Life (EOL) Indicator The EOL indicator is a user-programmable function. If the EOL indicator function is enabled, then approxi- mately every 15 days of continuous operation, TEOL, the circuit will read an age count stored in EEPROM, and will increment this age. After 10 years of operation, an audible indication will be given to signal that the unit should be replaced. The EOL indicator is the same as the chamber test failure warning. 3.9 Tone Pattern The smoke alarm tone pattern can be either a temporal pattern, or a continuous pattern, depending on the user’s selection. The temporal horn pattern supports the NFPA 72® National Fire Alarm and Signaling Code® for emergency evacuation signals. The continuous pattern is a 70% duty cycle continuous pattern. If a CO alarm is detected through the IO, the unit will sound the CO tone pattern. The CO tone pattern con- sists of 4 horn beeps in every 5.8s. Each horn beep is 100ms long and separated by 100ms. 3.10 Horn Synchronization The horn synchronization function is programmable by the user. In an interconnected system, if one unit goes into Local Alarm, other units will also go into Remote Alarm. The IO line is driven high by the origination local smoke unit, and stays high during the alarm. If the Horn Synchronization function is enabled, at the end of every temporal horn pattern and when the horn is off, the origination unit will drive IO low, then high again. This periodic IO pulsing high and low will cause the remote smoke units to go into and out of the Remote Alarm repeatedly. Each time a unit goes into a Remote Alarm, its timing is reset. The horn sound of all remote smoke units will be synchronized with the horn sound of the origination unit. A protection circuit ensures that the unit which goes into Local Alarm first will be the controlling unit that con- trols the horn synchronization. The units that go later into Local Alarm will not drive the IO line. This prevents bus contention problem. This function works with the temporal tone pattern only. 3.11 Auto Alarm Locate Auto Alarm Locate (AAL) is also a user-programmable function. To use AAL, the horn synchronization has to be selected first. The purpose of AAL is to let users quickly find the local alarm units just by listening. The local alarm units will sound the temporal pattern without interruption. The remote alarm units will sound the pat- tern with interruption. Every four temporal patterns (or 16s), the remote units are kept silenced for one pat- tern (or 4s). The originating unit conducts the IO cycling. Every four temporal patterns the IO is driven low for one temporal pattern. In the remaining three temporal patterns, the IO is still pulsing to keep the horn synchronized. The RLED of the origination unit and other local smoke units will be turned on 10 ms every 1s. The RLED of the remote smoke units will be off. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |