| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
RCM60 bảng dữ liệu(PDF) 9 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
RCM60 bảng dữ liệu(HTML) 9 Page - Bel Fuse Inc. |
|
9 / 16 page ![]() tech.support@psbel.com belfuse.com/power-solutions BCD.00989 Rev A, 14-Jun-2021 Page 9 of 16 RCM60 Series 60 W DC-DC Converters © 2021 Bel Power Solutions & Protection Description of Options General conditions: - T A = 25 °C, unless TC is specified. Option D: Output Voltage Monitor Option D encompasses an output voltage monitor by a solid state relay. When V o is in range, a solid state relay is activated (connecting OK1 with OK2). Max. data of relay contacts: 0.2 A /120 VDC Note: The trigger levels are typ. ±5 % of V o. Option Q: ORing FET for Redundant Systems The outputs of 2 parallel connected converters are separated with ORing diodes (built by FETs). If one converter fails, the remaining one must be capable to still deliver the full power to the load. If more power is needed, the system may be extended to more parallel converters (n+1 redundancy). Current sharing must be ensured by load lines of equal section and length. In addition, a slight droop characteristic of the output voltage and a negative temperature coefficient improve the load sharing as well. To keep the losses as small as possible, the ORing diode is replaced by a FET. The voltage drop is approx. 22 mV (not dependent of I o). Note: In the case of a failing converter, the output voltage is maintained by the redundant converters. However, the failing item should be identified and replaced. We recommend the Out OK function (option D). Option F: Incorporated Fuse The railway standard EN 50155 disadvises fuses in the converters. Consequently, the installer must preview an external fuse or circuit breaker. However, when this is not possible, an incorporated fuse is available (option F). This fuse is not accessible and will not trip, except if the converter is defect. Note: Converters with option F are protected against input reverse polarity by a series FET. Table 4: Recommended external fuses (same as incorporated with option F) Converter Specification 12RCM60 15 A fast acting XRCM60 8 A fast acting Option K: Pluggable Connectors This option allows the use of pre-assembled pluggable connectors; for details see Accessories. Note: Female connectors must be ordered separately. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |