background image
MODEL: R8-PC4A
R8-PC4A SPECIFICATIONS
ES-9795 Rev.4 Page 3/5
http://www.m-system.co.jp/
EXTERNAL VIEW
RUN
Module Address Setting
Rotary SW
Function Setting
DIP SW
Terminator DIP SW
1
0
9
1
0
9
SW1
x10
1 2 3 4 5 6 7 8
x1
SW2
SW4
SW3
Term
On
On
Status Indicator LED
Output Status Indicator LED
Internal Bus Connector
Output Connectors
FRONT VIEW
SIDE VIEW
CARD ADD.
PO1
PO2
PO3
PO4
1
0
9
1
0
9
OPERATING MODE SETTING
(*) Factory setting
■ Module Address
The left switch determines the tenth place digit, while the
right one does the ones place digit of the module address.
Address is selected between 0 to 30.
(Factory setting: 0)
Module Address Setting (x1)
Module Address Setting (x10)
1
0
9
1
0
9
■ Counter Reset (SW4-1)
1) Turn the power off.
2) Turn ON the Counter Reset SW (SW4-1).
3) Return the module to the base and turn the power supply ON.
The status indicator LED turns ON in amber.
4) Wait at least 5 seconds. Turn the power supply OFF.
5) Turn OFF the Counter Reset SW (SW4-1).
6) Return the module to the base and turn the power supply ON.
Note: Counter Reset SW must be turned OFF after this procedure
because the module does not start counting with ON state.
■ ON/OFF Pulse Width: (SW4-2, 3, 4, 5, 6, 7)
Setting for all outputs.
Setting for each output can be done with a PC.
ON
OFF
PULSE WIDTH
TIME *1
2
3
4
5
6
7
OFF
OFF
OFF
OFF
OFF
OFF
5 msec.(*)
ON
OFF
OFF
ON
OFF
OFF
10 msec.
OFF
ON
OFF
OFF
ON
OFF
15 msec.
ON
ON
OFF
ON
ON
OFF
100 msec.
OFF
OFF
ON
OFF
OFF
ON
500 msec.
ON
OFF
ON
ON
OFF
ON
1 sec.
OFF
ON
ON
OFF
ON
ON
1.5 sec.
ON
ON
ON
ON
ON
ON
2 sec.
*1. Minimum ensured time duration. For example, with 5 msec.
setting, the minimum pulse width is 5 msec. (Max. value =
Setting time + 2 msec.)
■ Configuration Mode
CONFIGURATION MODE
SW4
8
DIP switch setting (*)
OFF
PC Configurator and communication
ON
TERMINATOR SW
SW3
Without (*)
OFF
With
ON
■ Terminator DIP SW



Html Pages

1 2 3 4 5


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com