2 / 6 page ![]() MODEL: R3-PA16 R3-PA16 SPECIFICATIONS ES-8389 Rev.12 Page 2/6 https://www.m-system.co.jp/ INPUT SPECIFICATIONS Number of input: 16 points Input resistance: 6 kΩ Common: Negative commons, all points Maximum frequency: 100 Hz (ON/OFF time ≥ 5 msec.) This unit is designed to be able to accept a frequency up to 100 Hz, however, ‘chattering’ contact must be avoided for accurate measuring of such high frequency. Use mercury relays or similar ones that do not cause any chattering. Totalized pulse range: 1 – 10000 (‘0’ at reset) Max. pulse range selectable from 1 to 65535 using the R3CON PC Configurator Software. Refer to the R3CON Users Manual for detailed information. Count at overflow: Reset and restart at ‘1.’ ■ R3-PA16x (internal excitation) Sensing voltage: 13 V DC (max. 24 V with no load) ON current: ≥ 1.5 mA (≤ 1.5 kΩ) OFF current: ≤ 0.75 mA (≥ 18 kΩ) ■ R3-PA16x/A (external excitation) Sensing voltage: 24 V DC ON current: ≥ 1.5 mA (≤ 12 kΩ) OFF current: ≤ 0.75 mA (≥ 36 kΩ) INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 200 g (0.44 lb) PERFORMANCE Data allocation: 16 Current consumption: R3-PA16x: 100 mA R3-PA16x/A: 80 mA Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to internal bus or internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive FUNCTIONS ■ MANUAL COUNT RESET 1) Remove Network Module or its cables and interrupt communication with other devices. 2) Turn ON the Count Reset SW. 3) Return the module to the base and turn the power supply on. 4) ERR LED turns on and the module starts resetting its counter. When the resetting is complete, the LED turns to green. DO NOT remove the power while the red LED is on. The RUN LED starts blinking at the same time. 5) After the green LED is confirmed, turn the power supply off. 6) Turn OFF the Count Reset SW. 7) Return the Network module onto the base and turn the power supply on. Note: Count Reset SW must be turned OFF after this procedure because the module does not start counting with ON state. ■ REMOTE COUNT RESET INPUT With the Count Reset Input SW (SW3-3) turned ON, the Pi 16 pulse input can be used to remotely reset the count values. SW3-3 = OFF: Pi 16 is used as a pulse input. SW3-3 = ON: Pi 16 is used to reset the count values for the Pi 1 through Pi 15. One pulse supplied at the Pi 16 will be recognized as a reset signal. ■ REMOTE COUNT RESET OPERATION 1) ERR LED turns on (red color) when the reset signal is received. 2) In 1 second, the module starts resetting its counter. When the resetting is complete, the LED turns to green. 3) After 1 second, ERR LED turns back to the state before the reset signal has been received. Note: Reset signals received while the module is processing (1) through (3) are ignored. ■ COUNT RESET FROM HOST PC/PLC Refer to “COUNTER SETTING FROM HOST PC/PLC” section hereafter. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |