16 / 28 page ![]() LTM4657 16 Rev. A For more information www.analog.com Temperature Monitoring Measuring the absolute temperature of a diode is possible due to the relationship between current, voltage and tem- perature described by the classic diode equation: ID =IS •e VD η• VT ⎛ ⎝⎜ ⎞ ⎠⎟ or VD = η• VT •In ID IS where ID is the diode current, VD is the diode voltage, η is the ideal factor (typically close to 1.0) and IS (satura- tion current) is a process dependent parameter. VT can be broken out to: VT = k • T q where T is the diode junction temperature in Kelvin, q is the electron charge and k is Boltzmann’s constant. VT is approximately 26mV at room temperature (298K) and scales linearly with Kelvin temperature. It is this linear temperature relationship that makes diodes suitable tem- perature sensors. The IS term in the previous equation is the extrapolated current through a diode junction when the diode has zero volts across the terminals. The IS term varies from process to process, varies with temperature, and by definition must always be less than ID. Combining all of the constants into one term: KD = η•k q where KD = 8.62−5, and knowing ln(ID/IS) is always pos- itive because ID is always greater than IS, leaves us with the equation that: VD = T KELVIN ( )•KD •InID IS where VD appears to increase with temperature. It is common knowledge that a silicon diode biased with a current source has an approximate –2mV/°C temperature relationship (Figure 8), which is at odds with the equation. In fact, the IS term increases with temperature, reduc- ing the ln(ID/IS) absolute value yielding an approximate –2mV/°C composite diode voltage slope. APPLICATIONS INFORMATION Figure 8. Diode Voltage VD vs Temperature T(°C) TEMPERATURE (°C) –50 –25 0.3 0.5 0.8 0 50 75 0.4 0.7 0.6 25 100 4626 F08 125 To obtain a linear voltage proportional to temperature we cancel the IS variable in the natural logarithm term to remove the IS dependency from the equation 1. This is accomplished by measuring the diode voltage at two cur- rents I1, and I2, where I1 = 10 • I2) and subtracting we get: ∆VD = T(KELVIN)•KD•IN I1 IS – T(KELVIN)•KD•IN I2 IS Combining like terms, then simplifying the natural log terms yields: ΔVD = T(KELVIN) • KD • lN(10) and redefining constant K'D=KD•IN(10) = 198µV K yields ΔVD = K’D • T(KELVIN) Solving for temperature: T(KELVIN) = ∆VD K'D ( °CELSIUS)= T(KELVIN)–273.15 where 300°K = 27°C |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |