5 / 9 page ![]() 5 Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Indication Normal mode Green LED Yellow LED Power Output OFF OFF OFF OFF ON OFF ON OFF ON ON ON ON Output short circuit Green LED Yellow LED Output OFF Flashes 4Hz Yellow LED flashes minimum 1 sec. Teach by wire Out of the box (Factory settings): Typically, the sensor can be used without any additional calibration; it is designed to work with plastic tank walls of approximately 0,5 to 6 mm in thickness and glass walls of approximately 0,5 to 4 mm in thickness. It is important that the glass or plastic is nonconductive. Calibration: If the factory settings are insufficient, the sensor is teachable to either Full or Empty. Calibration Full: The sensor switch point is set below the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the full calibration on a full tank or tube will be sufficient. In critical applications with large variations in media type and temperature, it can be an advantage to teach the Full level with approximately 50 % of the active sensing surface covered. Full calibration procedure: •Connect teach wire to V+ for 2 - 7 seconds •The green LED flashes 1 imp. per sec. and the yellow LED is OFF •After successful calibration, the yellow LED flashes 3 times (with 1 Hz) Calibration Empty: The sensor switch point is set above the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the Empty calibration on an empty tank or tube will be sufficient. In critical applications with a high amount of residue film, moisture or foam build-up, an Empty calibration can be performed with the build-up present. Empty calibration procedure: •Connect teach wire to V+ for 7 - 12 seconds •The green LED flashes 1 imp. per sec. and the yellow LED is ON •After successful calibration, the yellow LED flashes 3 times (with 1 Hz) Cancel calibration procedure: •Keep the teach wire connected to V+ for more than 14 seconds to abort teach procedure. The switch points will remain unchanged. •The green LED is off and the yellow LED flashes (4 Hz) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |