9 / 30 page ![]() F0453C Datasheet © 2020 Renesas Electronics Corporation 9 May 1, 2020 Parameter Symbol Condition Minimum Typical Maximum Units Power ON from Standby Mode [b] SWON_STANDBY To Rx Mode from Standby Mode 50% STBY to RF output settled within ±0.1dB of final value 1 µs Power OFF to Standby Mode [b] SWOFF_STANDBY To Standby Mode from Rx Mode 50% STBY to gain below -25dB from max gain 1 µs [a] Items in the Minimum/Maximum columns in bold italics are guaranteed by test. Items in the Minimum/Maximum columns NOT in bold italics are guaranteed by design characterization. [b] fRF = 3500MHz. Assumes the control signal is clean and no external RC circuitry is required on the pin. Adding RC circuitry increases switching time. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|