13 / 21 page ![]() Vertical and Planar Hall-Effect Switches APS11000 and APS11060 13 Allegro MicroSystems 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com Functional Safety The APS11000 and APS11060 were designed in accordance with the international standard for automotive functional safety, ISO 26262:2011. These products achieve an ASIL (Automotive Safety Integrity Level) rating of ASIL A (pending confirmation) according to the standard. The APS11000 and APS11060 are both classified as a SEooC (Safety Element out of Context) and can be easily inte- grated into safety-critical systems requiring higher ASIL ratings that incorporate external diagnostics or use measures such as redun- dancy. Safety documentation will be provided to support and guide the integration process. For further information, contact your local FAE for A2-SIL™ documentation: www.allegromicro.com/ASIL. Operation The APS11000 and APS11060 are integrated Hall-effect sensor ICs with an open-drain output. Table 1 offers a guide for select- ing the output polarity configuration, further explained in the configuration sections below. The open-drain output is an NMOS transistor that actuates in response to a magnetic field. The direc- tion of the applied magnetic field is perpendicular to the branded face for the APS11000, and parallel with the branded face for the APS11060; see Figure 5 for an illustration. The devices are offered in two packages: the UA package, a 3-pin through-hole mounting configuration, or in the LH package, a 3-pin surface- mount configuration. See the Selection Guide for a complete list of available options. Configurations xSL and xSH. The unipolar output of these devices is actuated when a south-polarity magnetic field perpen- dicular to the Hall element exceeds the operate point threshold, BOPS. When BOPS is exceeded, the xSL output turns on (goes low). The xSH is complementary, in that for this device the output turns off (goes high) when BOPS is exceeded. When the magnetic field is removed or reduced below the release point, BRPS, the device outputs return to their original state—off for the xSL and on for the xSH. See Figure 3 for unipolar south switching behav- ior. Configurations xNL and xNH. The unipolar output of these devices is actuated when a north-polarity magnetic field perpen- dicular to the Hall element exceeds the operate point threshold, BOPN. When BOPN is exceeded, the xNL output turns on (goes low). The xNH is complementary, in that for this device the output turns off (goes high) when BOPN is exceeded. When the magnetic field is removed or reduced below the release point, BRPN, the device outputs return to their original state—off for the xNL and on for the xNH. See Figure 3 for unipolar north switching behavior. Table 1: Switch Polarity Configuration Options Part Number Suffix Operating Mode Output State for B > BOP Output State for B = 0 G Power-On State, t < tPO xSL Unipolar South Low High High xSH Unipolar South High Low High xNL Unipolar North Low High High xNH Unipolar North High Low High xPL Omnipolar Low High High xPH Omnipolar High Low High Configurations xPL and xPH. The omnipolar operation of these devices allows actuation with either a north or a south polarity field. The xPL operates using the standard output polarity conven- tion. Fields exceeding the operating points, BOPS or BOPN, will turn the output on (low). When the magnetic field is removed or reduced below the release point, BRPN or BRPS, the device output turns off (goes high). The xPH is complementary, in that for the device, a north or south polarity field exceeding the operate points, BOPS or BOPN, will turn the output off (high). Removal of the field, or reduction below the release point threshold, BRPS or BRPN, will turn the output on (low). See Figure 3 for omnipolar switching behavior. After turn-on, the output transistor is capable of sinking current up to the short circuit current limit, IOM, which is a minimum of 15 mA. The difference in the magnetic operate and release points is the hysteresis, BHYS, of the device. This built-in hysteresis allows clean switching of the output even in the presence of exter- nal mechanical vibration and electrical noise. Figure 5: Magnetic Sensing Orientations APS11000 LH (Panel A), APS11000 UA (Panel B), APS11060 LH (Panel C), and APS11060 UA (Panel D) 2 - |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |