công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

PLMK04832W/EM bảng dữ liệu(PDF) 89 Page - Texas Instruments

tên linh kiện PLMK04832W/EM
Giải thích chi tiết về linh kiện  LMK04832-SP Space Grade Ultra-Low-Noise JESD204B Dual-Loop Clock Jitter Cleaner
PDF  98 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  TI [Texas Instruments]
Trang chủ  http://www.ti.com
Logo TI - Texas Instruments

PLMK04832W/EM bảng dữ liệu(HTML) 89 Page - Texas Instruments

Back Button PLMK04832W/EM Datasheet HTML 85Page - Texas Instruments PLMK04832W/EM Datasheet HTML 86Page - Texas Instruments PLMK04832W/EM Datasheet HTML 87Page - Texas Instruments PLMK04832W/EM Datasheet HTML 88Page - Texas Instruments PLMK04832W/EM Datasheet HTML 89Page - Texas Instruments PLMK04832W/EM Datasheet HTML 90Page - Texas Instruments PLMK04832W/EM Datasheet HTML 91Page - Texas Instruments PLMK04832W/EM Datasheet HTML 92Page - Texas Instruments PLMK04832W/EM Datasheet HTML 93Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 89 / 98 page
background image
9.2.2.1.1 Clock Architect
Under the advanced tab of the Clock Architect, filtering of specific parts can be done using regular expressions
in the Part Filter box. [LMK04832.*] will filter for only the LMK04832 device (without brackets). More detailed
filters can be given such as the entire part name LMK04832_VCO0 to force an LMK04832 using VCO0 solution
if one is available.
9.2.2.2 Device Configuration and Simulation
The tools automatically configure the simulation to meet the input and output frequency requirements given, and
make assumptions about other parameters to give some default simulations. However, the user may chose to
make adjustments for more accurate simulations to their application. For example:
• Entering the VCO Gain of the external VCXO or possible external VCO used device.
• Adjust the charge pump current to help with loop filter component selection. Lower charge pump currents
result in smaller components but may increase impacts of leakage and at the lowest values reduce PLL
phase nosie performance.
• Clock Architect allows loading a custom phase noise plot for reference or VCXO block. Typically, a custom
phase noise plot is entered for CLKin to match the reference phase noise to device; a phase noise plot for the
VCXO can additionally be provided to match the performance of VCXO used. For improved accuracy in
simulation and optimum loop filter design, be sure to load these custom noise profiles for use in application.
• PLLatinum Sim can also be used to design and simulate a loop filter.
9.2.2.3 Device Programming
Using the clock design tools configuration the TICS Pro software is manually updated with this information to
meet the required application.
Frequency planning for assignment of outputs:
• To minimize crosstalk perform frequency planning / CLKout assignments to keep common frequencies on
outputs close together.
• It is best to place common device clock output frequencies on outputs sharing the same VCC group. For
example, these outputs share Vcc4_CG2. Refer to Section 5 to see the VCC groupings the clock outputs.
In this example, the 245.76-MHz ADC output needs the best performance. CLKout2 provides the best noise
floor / performance. The 245.76 MHz is placed on CLKout2 with 10.24-MHz SYSREF on CLKout3.
• For best performance the input and output drive level bits may be set. Best noise floor performance is
achieved with CLKout2_3_IDL = 1 and CLKout2_3_ODL = 1.
• The CLKoutX_Y_ODL bit has no impact on even clock outputs in high performance bypass mode.
In this example, the 983.04-MHz DAC output is placed on CLKout4 and CLKout6 with 10.24-MHz SYSREF on
paired CLKout5 and CLKout7 outputs.
• These outputs share Vcc4_CG2.
In this example, the 122.88-MHz FPGA JESD204B output is placed on CLKout10 with 10.24-MHz SYSREF on
paired CLKout11 output.
Additionally, the 122.88-MHz FPGA non-JESD204B outputs are placed on CLKout8 and CLKout9.
• When frequency planning, consider PLL2 as a clock output at the phase detector frequency. As such, these
122.88-MHz outputs have been placed on the outputs close to the PLL2 and Charge Pump power supplies.
Once the device programming is completed as desired in the TICS Pro software, it is possible to export the
register settings from the Register tab for use in application.
9.2.3 Application Curves
Required Section for RTM
www.ti.com
LMK04832-SP
SNAS698B – MAY 2020 – REVISED DECEMBER 2020
Copyright © 2020 Texas Instruments Incorporated
Submit Document Feedback
89
Product Folder Links: LMK04832-SP



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com