| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
UBX-15025564-R16 bảng dữ liệu(PDF) 15 Page - u-blox AG |
|
|
|||||||||||||||||||||||||||||
UBX-15025564-R16 bảng dữ liệu(HTML) 15 Page - u-blox AG |
|
15 / 30 page ![]() SARA-N2 series - Data Sheet UBX-15025564 - R16 Electrical specification Page 15 of 30 4.2 Operating conditions ☞ Unless otherwise indicated, all operating condition specifications are at an ambient temperature of +25 °C. ⚠ Operation beyond the operating conditions is not recommended and extended exposure beyond them may affect device reliability. 4.2.1 Operating temperature range Parameter Min. Typical Max. Unit Remarks Operating temperature range -40 +85 °C -20 +85 °C Normal operating temperature range -40 -20 °C Extended operating temperature range Table 8: Environmental conditions 4.2.1.1 Normal operating temperature range The module is fully functional and meets the 3GPP specification across the specified temperature range. 4.2.1.2 Extended operating temperature range The module is fully functional across the specified temperature range. Occasional deviations from the 3GPP specification may occur. 4.2.2 Supply/power pins Pin Name Parameter Min Typ Max Unit VCC Module supply normal operating input voltage1 3.10 3.60 4.00 V Module supply extended operating input voltage2 2.75 4.20 V Table 9: Input characteristics of Supply/Power pins Pin Name Parameter Min Typ Max Unit VSIM SIM supply output voltage 1.80 V V_INT Generic Digital Interfaces supply output voltage 1.80 V I_INT Generic Digital Interfaces supply output current capability 80 mA Table 10: Output characteristics of Supply/Power pins 1 Input voltage at VCC pins must be above the normal operating range minimum limit to switch-on the module. 2 Occasional deviations from the 3GPP specifications may occur. The RF power transmitted by the module may be few dB lower than expected when operating below the minimum value of the normal operating range. Ensure that input voltage at VCC never drops below the extended operating range minimum limit during module operation to avoid possible module switch-off events. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |