| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PCM4108CPAPT bảng dữ liệu(PDF) 4 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PCM4108CPAPT bảng dữ liệu(HTML) 4 Page - Texas Instruments |
|
4 / 39 page ![]() PCM4108 SBAS354 − JUNE 2005 www.ti.com 4 ELECTRICAL CHARACTERISTICS (continued) All parameters are specified at TA = +25°C with VCC = +5V, VDD = +3.3V, and a measurement bandwidth from 10Hz to 20kHz, unless otherwise noted. System clock frequency is equal to 256fS for Single and Dual Rate sampling modes, and 128fS for Quad Rate sampling mode. PCM4108 PARAMETER UNITS MAX TYP MIN CONDITIONS DYNAMIC PERFORMANCE WITH 24-BIT DATA(1) fS = 48kHz Total harmonic distortion + noise THD+N f = 1kHz at 0dBFS −100 −94 dB Total harmonic distortion + noise THD+N f = 1kHz at −60dBFS −56 dB Dynamic range, A-weighted f = 1kHz at −60dBFS 112 118 dB Idle channel SNR, A-weighted All zero input data 119 dB Idle channel SNR, unweighted All zero input data 116 dB Channel separation f = 1kHz at 0dBFS for active channel 100 110 dB fS = 96kHz Total harmonic distortion + noise THD+N f = 1kHz at 0dBFS, BW = 10Hz to 40kHz −100 dB Total harmonic distortion + noise THD+N f = 1kHz at −60dBFS, BW = 10Hz to 40kHz −53 dB Dynamic range, A-weighted f = 1kHz at −60dBFS 118 dB Idle channel SNR, A-weighted All zero input data 119 dB Idle channel SNR, unweighted All zero input data, BW = 10Hz to 40kHz 113 dB Channel separation f = 1kHz at 0dBFS for active channel 110 dB fS = 192kHz Total harmonic distortion + noise THD+N f = 1kHz at 0dBFS, BW = 10Hz to 40kHz −97 dB Total harmonic distortion + noise THD+N f = 1kHz at −60dBFS, BW = 10Hz to 40kHz −53 dB Dynamic range, A-weighted f = 1kHz at −60dBFS 118 dB Idle channel SNR, A-weighted All zero input data 118 dB Idle channel SNR, unweighted All zero input data, BW = 10Hz to 40kHz 113 dB Channel separation f = 1kHz at 0dBFS for active channel 110 dB DYNAMIC PERFORMANCE WITH 16-BIT DATA fS = 44.1kHz Total harmonic distortion + noise THD+N f = 1kHz at 0dBFS −92 dB Total harmonic distortion + noise THD+N f = 1kHz at −60dBFS −33 dB Dynamic range, A-weighted f = 1kHz at −60dBFS 96 dB Idle channel SNR, A-weighted(2) All zero input data 118 dB Idle channel SNR, unweighted(2) All zero input data 115 dB (1) Dynamic performance parameters are measured using an Audio Precision System Two Cascade or Cascade Plus test system. Input data word length is 24 bits with triangular PDF dither added for dynamic range and THD+N tests. Idle channel SNR is measured with both the soft and zero data mute functions disabled and 0% full-scale input data with no dither applied. The measurement bandwidth is limited by using the Audio Precision 10Hz high-pass filter in combination with either the AES17 20kHz low-pass filter or AES17 40kHz low-pass filter. All A-weighted measurements are performed using the Audio Precision A-weighting filter in combination with either the 22kHz or 80kHz low-pass filter. Measurement mode is set to RMS for all parameters. The AVERAGE measurement mode will yield better typical performance numbers. (2) Idle Channel SNR is not limited by word length. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |