| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
BQ28Z610-R1 bảng dữ liệu(PDF) 24 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28Z610-R1 bảng dữ liệu(HTML) 24 Page - Texas Instruments |
|
24 / 32 page ![]() Battery Gauge Charger Boost Converter MCU Audio Power Amp Audio Processor Pack Side System Side 2 I C Power Copyright © 2017, Texas Instruments Incorporated 24 BQ28Z610-R1 SLUSE07 – JANUARY 2020 www.ti.com Product Folder Links: BQ28Z610-R1 Submit Documentation Feedback Copyright © 2020, Texas Instruments Incorporated Typical Applications (continued) Figure 22. Wireless (Bluetooth) Speaker Application Block Diagram 9.2.1 Design Requirements (Default) Design Parameter Example Cell Configuration 2s1p (2-series with 1 Parallel) Design Capacity 4400 mAh Device Chemistry 100 (LiCoO2/graphitized carbon) Cell Overvoltage at Standard Temperature 4300 mV Cell Undervoltage 2500 mV Shutdown Voltage 2300 mV Overcurrent in CHARGE Mode 6000 mA Overcurrent in DISCHARGE Mode –6000 mA Short Circuit in CHARGE Mode 0.1 V/Rsense across SRP, SRN Short Circuit in DISCHARGE 1 Mode –0.1 V/Rsense across SRP, SRN Safety Over Voltage 4500 mV Cell Balancing Disabled Internal and External Temperature Sensor Enabled Under Temperature Charging 0°C Under Temperature Discharging 0°C BROADCAST Mode Enabled 9.2.2 Detailed Design Procedure 9.2.2.1 Setting Design Parameters For the firmware settings needed for the design requirements, refer to the BQ28Z610-R1 Technical Reference Manual (SLUUC81). • To set the 2s1p battery pack, go to data flash Configuration: DA Configuration register's bit 0 (CC0) = 1. • To set design capacity, set the data flash value to 4400 in the Gas Gauging: Design: Design Capacity register. • To set device chemistry, go to data flash SBS Configuration: Data: Device Chemistry. The BQSTUDIO software automatically populates the correct chemistry identification. This selection is derived from using the BQCHEM feature in the tools and choosing the option that matches the device chemistry from the list. • To protect against cell overvoltage, set the data flash value to 4300 in Protections: COV: Standard Temp. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |