| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
05200033 bảng dữ liệu(PDF) 3 Page - Testo SE & Co. KGaA |
|
|
|||||||||||||||||||||||||||||
05200033 bảng dữ liệu(HTML) 3 Page - Testo SE & Co. KGaA |
|
3 / 8 page ![]() Sensor types testo 435-2/-4 testo 435-3/-4 Lux Measuring range 0 to +100000 Lux Accuracy ±1 digit See probe data Resolution / Overload 1 Lux; 0.1 Hz Differential pressure probe, internal 0 to +25 hPa ±0.02 hPa (0 to +2 hPa) ±1% of mv (remaining range) 0.01 hPa / 200 hPa testo 435 Technical data testo 435-1 testo 435-2 testo 435-3 testo 435-4 XXXX XXXX X X X X X XX X X X XX XXX X X XX X XX XX XX XX XX XX XXXX IAQ probe for the measurement of CO 2, air temperature, indoor air humidity and absolute pressure Thermal flow velocity probe with integrated temperature and air humidity measurement Vane and hot wire probes Temperature probe for immersion/penetration, air and surface measurements Wireless probes for temperature measurements Ambient CO probe Absolute pressure probe Integrated differential pressure measurement for flow velocity measurement with Pitot tube and for monitoring filters (not retro-fittable) Comfort probe for degree of turbulence measurement for the objective evaluation of the air velocity in a room Humidity probe for air temperature and air humidity measurements Wireless probe for air temperature and air humidity measurement Lux probe for the measurement of light intensity Temperature probe for determining U-value Instrument equipment Easy operation with user profiles XXXX Illuminated display XXXX Testo fast printer for documenting measurement data (optional) XX Instrument store for 10000 measurement values (not retro-fittable) XX PC software for the analysis, archiving and documentation of the readings Connectable probes (optional) Overview of versions testo 435 The table provides a fast overview of the connectable probes and the instrument equipment per version. We measure it. Sensor types testo 435-1/-2/-3/-4 NTC Measuring range -50 to +150 °C Accuracy ±1 digit ±0.2 °C(-25 to +74.9 °C) ±0.4 °C (-50 to -25.1 °C) ±0.4 °C (+75 to +99.9 °C) ±0.5% of mv (remaining range) Resolution 0.1 °C Type K (NiCr-Ni) -200 to +1370 °C ±0.3 °C (-60 to +60 °C) ±(0.2 °C +0.5% of mv) (remaining range) 0.1 °C Type T (Cu-CuNi) -200 to +400 °C ±0.3 °C (-60 to +60 °C) ±(0.2 °C +0.5% of mv) (remaining range) 0.1 °C Testo humid. sensor, cap. 0 to +100 %RH See probe data 0.1 %RH Vane Measuring range 0 to +60 m/s Accuracy ±1 digit See probe data Resolution 0.01m/s (60 + 100 mm Vane) 0.1 m/s (16 mm Vane) Hot wire 0 to +20 m/s See probe data 0.01 m/s Absolute pressure probe 0 to +2000 hPa See probe data 0.1 hPa CO 2 (IAQ probe) 0 to +10000 ppm CO 2 See probe data 1 ppm CO 2 testo-435-P03 06.08.2013 14:31 Seite 3 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |