2 / 5 page ![]() 1. Remove luminaire from packaging and inspect for damage before installing. 2. Locate the supplied surface mount brackets. (For suspended installation, refer to the separate hanging bracket kit and instructions.) 3. Insert the screws into the bracket and then screw on the t-nuts. Attach bracket assembly to luminaire housing as shown. Fully tighten the screws to lock in place. 4. Place the light in the mounting location and mark the positions of the bracket mounting holes. 5. Drill the holes and use the appropriate screws to secure the luminaire to the mounting location. CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305 mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305 mm by 1350 mm. Wiring the WLB92 Industrial LED Light Bar Follow these steps to wire your WLB92 Industrial LED Light Bar AC Conduit models. Pull latch out to release or insert wire Remove access cap 1/2” Trade Size Knockouts Wiring Chamber 1. Loosen the screws to remove the access cap from the wiring chamber. 2. Connect the power. • To connect the power from the back of the luminaire, remove the knockout from the back of the access cap and install either 1/2-inch conduit or an AC power cord with strain relief. • To connect the power from the side of the luminaire: remove the knockout from the side of the access cap and install either 1/2-inch conduit or an AC power cord with strain relief on the luminaire wires. • If using rigid conduit, the conduit hub/connector must be approved for use in dry or damp locations and must be connected to the conduit before the hub/connector is connected to the luminaire. 3. Pull the luminaire wires out of the wiring chamber, then pull the field wires through the knockouts and out of the wiring chamber. 4. Lift the latch a full 90° on the unused terminal block locations and make the following electrical connections: a) Connect the green/yellow luminaire wire to the AC ground power wire b) Connect the white luminaire wire to the AC neutral power wire c) Connect the black luminaire wire to the AC line power wire d) If using 0–10 V analog dimming, connect the purple luminaire wire to the positive dimming wire e) If using 0–10 V analog dimming, connect the gray luminaire wire to the negative dimming wire 5. Close the latches on each terminal block when you have finished wiring, and push all wires back into the wiring chamber. 6. Re-attach the access cap to the wiring chamber. 7. Repeat steps 1 through 5 on other end of the luminaire if you are connecting to more than one luminaire in a continuous run. Wiring Diagram Diagram Wire Connection N L Dim (+) Dim (-) N L Dim (+) Dim (-) L - Black Line/Hot N - White Neutral - Green/Yellow Earth ground Dim (+) - Purple 0–10 V dc analog dimming Dim (-) - Gray Return analog dimming WLB92 Industrial LED Light Bar (AC Conduit) 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183985 Rev. I |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |