Back Button BUL44D2 Datasheet HTML 4Page - ON Semiconductor BUL44D2 Datasheet HTML 5Page - ON Semiconductor BUL44D2 Datasheet HTML 6Page - ON Semiconductor BUL44D2 Datasheet HTML 7Page - ON Semiconductor BUL44D2 Datasheet HTML 8Page - ON Semiconductor BUL44D2 Datasheet HTML 9Page - ON Semiconductor BUL44D2 Datasheet HTML 10Page - ON Semiconductor BUL44D2 Datasheet HTML 11Page - ON Semiconductor BUL44D2 Datasheet HTML 12Page - ON Semiconductor  
Zoom Inzoom in Zoom Outzoom out
 9 / 12 page
background image
BUL44D2
9
Motorola Bipolar Power Transistor Device Data
SECOND BREAKDOWN
DERATING
THERMAL DERATING
Figure 23. Forward Bias Safe Operating Area
10
0.01
1000
10
VCE, COLLECTOR–EMITTER VOLTAGE (VOLTS)
Figure 24. Reverse Bias Safe Operating Area
2.5
1
0
900
200
VCE, COLLECTOR–EMITTER VOLTAGE (VOLTS)
100
1
0.1
DC
5 ms
1 ms
10
µs
1
µs
0.5
0 V
–1.5 V
– 5 V
TC ≤ 125°C
GAIN
≥ 4
LC = 500 µH
300
400
700
600
2
1.5
TYPICAL CHARACTERISTICS
500
800
Figure 25. Forward Bias Power Derating
1
0
160
100
20
TC, CASE TEMPERATURE (°C)
0.8
0.6
0.4
0.2
60
140
40
80
120
There are two limitations on the power handling ability of a
transistor: average junction temperature and second break-
down. Safe operating area curves indicate IC –VCE limits of
the transistor that must be observed for reliable operation;
i.e., the transistor must not be subjected to greater dissipa-
tion than the curves indicate. The data of Figure 23 is based
on TC = 25°C; TJ(pk) is variable depending on power level.
Second breakdown pulse limits are valid for duty cycles to
10% but must be derated when TC > 25°C. Second
breakdown limitations do not derate the same as thermal
limitations. Allowable current at the voltages shown on
Figure 23 may be found at any case temperature by using
the appropriate curve on Figure 25.
TJ(pk) may be calculated from the data in Figure 26. At any
case temperatures, thermal limitations will reduce the power
that can be handled to values less than the limitations
imposed by second breakdown. For inductive loads, high
voltage and current must be sustained simultaneously during
turn–off with the base to emitter junction reverse biased. The
safe level is specified as a reverse biased safe operating
area (Figure 24). This rating is verified under clamped
conditions so that the device is never subjected to an
avalanche mode.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com