| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
HM8563 bảng dữ liệu(PDF) 7 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
|
|||||||||||||||||||||||||||||
HM8563 bảng dữ liệu(HTML) 7 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
7 / 22 page ![]() • 6 • 2.7.1 Control/Status 1 register Table 6 Control/Status 1 register bits description 00H Symbol Description b7 TEST1 TEST1 = 0; normal mode. TEST1 = 1; EXT_CLK test mode; see Section 8.7. b5 STOP STOP = 0; RTC source clock runs. STOP = 1; all RTC divider chain flip-flops are asynchronously set to logic 0; the RTC clock is stopped (CLKOUT at 32.768 kHz is still available). b3 TESTC TESTC = 0; power-on reset override facility is disabled (set to logic 0 for normal operation). TESTC = 1; power-on reset override is enabled. b6, b4, b2..0 - By default set to logic 0. 2.7.2 Control/Status 2 register Table 7 Description of Control/Status 2 register bits description 01H Symbol Description b7..5 0 By default set to logic 0 b4 TI/TP TI/TP = 0: INT is active when TF is active (subject to the status of TIE). TI/TP = 1: INT pulses active according to Table 8 (subject to the status of TIE). Note that if AF and AIE are active then INT will be permanently active. b3 AF When an alarm occurs, AF is set to logic 1. Similarly, at the end of a timer countdown, TF is set to logic 1. These bits maintain their value until overwritten by software. If both timer and alarm interrupts are required in the application, the source of the interrupt can be determined by reading these bits. To prevent one flag being overwritten while clearing another, a logic AND is performed during a write access. See Table 9 for the value descriptions of bits AF and TF. b2 TF b1 AIE Bits AIE and TIE activate or deactivate the generation of an interrupt when AF or TF is asserted, respectively. The interrupt is the logical OR of these two conditions when both AIE and TIE are set. AIE = 0: alarm interrupt disabled; AIE = 1: alarm interrupt enabled. TIE = 0: timer interrupt disabled; TIE = 1: timer interrupt enabled. b0 TIE Table 8 ——— INT operation (bit TI/TP = 1) Source clock (Hz) ——— INT period(s) n=1 n>1 4096 1/8192 1/4096 64 1/128 1/64 1 1/64 1/64 1/60 1/64 1/64 Note: [1] TF and ——— INT become active simultaneously. [2] n = loaded countdown timer value. Timer stopped when n = 0. HM8563 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |