2 / 2 page ![]() 10. CR#31: it is used to set RS-485 communication address. Setting range is 01~255 and factory setting is K1. 11. CR#32 is used to set RS-485 communication baud rate: 4800, 9600, 19200, 38400, 57600, 115200 bps. b0: 4800bps. b1: 9600bps. (factory setting) b2: 19200bps. b3: 38400 bps. b4: 57600 bps. b5: 115200 bps. b6-b13: reserved. b14: exchange low and high byte of CRC check code. (only for RTU mode) b15=0: ASCII mode. b15=1: RTU mode. Communication format: ASCII mode is 7Bit, even bit, 1 stop bit (7 E 1). Communication format of RTU mode is 8Bit, even bit, 1 stop bit (8 E 1). 12. CR#33 is used to set the internal function priority, such as characteristic register. Output latched function will save output setting in the inner memory before power loss. 13. CR#34: software version. 14. CR#35~ CR#48: system used. 15. The corresponding parameters address H4000~H4030 of CR#0~CR#48 are provided for user to read/write data through RS-485. A. Communication baud rate: 4800, 9600, 19200, 38400, 57600, 115200 bps. B. Communication format: ASCII mode is 7Bit, even bit, 1 stop bit (7 E 1). Communication format of RTU mode is 8Bit, even bit, 1 stop bit (8 E 1). C. Function code: 03H—read data from register. 06H—write one WORD into register. 10H—write multiple WORD into registers. 5 ADJUST A/D CONVERSION CHARACTERISTIC CURVE 5.1 Adjust A/D Conversion Characteristic Curve Voltage input mode Mode 0 of CR#1 GAIN=5V (4000LSB), OFFSET=0V (0LSB) Mode 1 of CR#1 GAIN=6V (4800LSB), OFFSET=2V (1600LSB) GAIN: Voltage input value when digital output is 4000. Setting range is -4V~+20V (-3200LSB~ +16000LSB) OFFSET: Voltage input value when digital output is 0. Setting range: -5V~+5V (-4000LSB ~ +4000LSB) +8000 +4000 -4000 10V -8000 -6V -10V 6V 5V 2V 0 GAIN OFFSET Digital output Voltage input mode 0 mode 1 GAIN-OFFSET: Setting range is +1V~+15V (+800LSB~ +12000LSB) Current input mode: Mode 2 of CR#1 GAIN = 20mA (4000LSB), OFFSET=4mA (800LSB). Mode 3 of CR#1 GAIN = 20mA (4000LSB), OFFSET=0mA (0LSB). GAIN: Current input value when digital output is +4000. Setting range is -20 mA~+20 mA (-4000LSB ~ +4000LSB ) OFFSET: Current input value when digital output value is 0. Setting range is-16 mA ~+52 mA (-3200LSB ~ +10400LSB) +4000 -4000 -12mA -20mA 4mA 0 OFFSET 20mA GAIN Digital output current input mode 3 mode 2 GAIN-OFFSET: Setting range is +4mA ~ +32mA (800LSB~ +6400LSB) Using charts above to adjust A/D conversion characteristic curve of voltage input mode and current input mode. Users can adjust conversion characteristic curve by changing OFFSET values (CR#18~CR#21) and GAIN values (CR#24~CR#27) depend on application. LSB(Least Significant Bit): 1. voltage input: 1LSB=10V/8000=1.25mV. 2. current input: 1LSB=20mA/4000=5µA. 5.2. Program Example for Adjusting A/D Conversion Characteristics Curve Example 1: setting OFFSET value of CH1 to 0V(=K0LSB) and GAIN value of CH1 to 2.5V(=K2000LSB). X0 K2000 K24 H0 K1 K0 K1 H0 K1 M1002 K0 K33 K1 K0 K1 K18 K0 K0 TO TO TO TO Writing H0 to CR#1 of analog input module no. 0 and set CH1 to mode 0 (voltage input -10V~+10V) Writing H1 to CR#33 and allow to adjust characters of CH1~CH4. When X0 switches from Off to On, K0LSB of OFFSET value will be wrote in CR#18 and K2000LSB of GAIN value will be wrote in CR#24. Example 2: setting OFFSET value of CH2 to 2mA(=K400 LSB) and GAIN value of CH2 to 18 mA (=K3600LSB) X0 K1 K0 K1 H0 K1 M1002 K0 K33 K1 K0 K1 K0 H18 K19 K25 K400 K3600 TO TO TO TO Writing H18 to CR#1 of analog input mode no. 0 and set CH2 to mode 3 (current input: -20 mA ~ +20mA) Writing H0 to CR#33 and allow to adjust characteristics of CH4. When X0 switches from Off to On, K400LSB of OFFSET value will be wrote in CR#19 and K3600LSB of GAIN value will be wrote in CR#25. 6 INITIAL PLC START-UP Lamp display: 1. When power is on, POWER LED will be lit and ERROR LED will be lit for 0.5 second. 2. Normal run: POWER LED should be lit and ERROR LED should turn off. When power supply is lower than 19.5V, ERROR LED will blink continuously till the power supply goes higher than 19.5V. 3. When it connects to PLC MPU in series, RUN LED on MPU will be lit and A/D LED or D/A LED should blink. 4. After receiving the first RS-485 instruction during controlling by RS-485, A/D LED or D/A LED should blink. 5. After converting, ERROR LED should blink if input or output exceeds upper bound or lower than lower bound. Example: K1 K0 K1 K1 K0 K0 K0 M1000 FROM TO END K2 K6 D0 H3030 K32 D20 K4 FROM TO K0 K2 = H400 D0 M1002 = H400 D0 Explanation: Read the data of model type from extension module K0 and distinguish if the data is H400 (DVP04AD-H model type). If the model type is DVP04AD-H, M11 is on and the setting input mode is (CH1, CH3)= mode 0, (CH2, CH4)= mode 3. Set the number of times for average of CH1 and CH2 are K32. Read the input signal average value of CH1~CH4 (4 data) and saved into D20~D23. 7 RELATED INSTRUCTIONS EXPLANATION API Applicable model ES EP EH 78 D FROM P Read special module CR data Bit device Word device X Y M S K H KnX KnY KnM KnS T C D E F m1 m2 D n Note: The usage range of operand m1 is 0~7. The usage range of operand m2: ES/EP: 0-48, EH: 0-254. The usage range of operand n: ES/EP: n= 1~(49-m2), EH: 1~(255-m2). ES series model doesn’t support pulse execution instruction (FROMP, DFROMP). 16-bit instruction (9 STEPS) FROM Continuous execution FROMP Pulse execution 32-bit instruction (17 STEPS) DFROM Continuous execution DFROMP Pulse execution Flag: When M1083=On, it allows to insert interrupt during FROM/TO. Refer to following for detail. Command Explanation : the number for special module. : the number of CR (Control Register) of special module that will be read. : the location to save reading data. : the data number of reading one time. DVP-series PLC uses this instruction to read CR data of special module. : When assigning bit operand, K1~K4 are used for 16-bit and K5~K8 are used for 32-bit. Please refer the footnote below for the calculation of special module number. Program Example To read the content of CR#24 of special module#0 to D0 of PLC and to read the content of CR#25 of special module#0 to D1 of PLC. It can read 2 data in one time (n=2). The instruction will be executed when X0=On. The instruction won’t be executed when X0=Off and the content of previous reading data won’t change. X0 FROM K0 K24 D0 K2 API Applicable model ES EP EH 79 D TO P Special module CR data write in Bit device Word device X Y M S K H KnX KnY KnM KnS T C D E F m1 m2 S n Note: The usage range of operand m1 is 0~7. The usage range of operand m2: ES/EP: 0-48, EH: 0-254. The usage range of operand n: ES/EP: n= 1~(49-m2), EH: 1~(255-m2). For ES series, it doesn’t support pulse execution instruction (TOP, DTOP) 16-bit instruction (9 STEPS) TO Continuous execution TOP Pulse execution 32-bit instruction (17 STEPS) DTO Continuous execution DTOP Pulse execution Flag: When M1083=On, it allows to insert interrupt during FROM/TO. Refer to following for detail. Command Explanation : the number of special module. : the number of CR (Control Register) of special module that will be wrote in. : the data to write in CR. : the data number to write in one time. DVP-series PLC uses this instruction to write data into CR of special module. : When assigning bit operand, K1~K4 can be used for 16-bit and K5~K8 can be used for 32-bit. Program Example Using 32-bit instruction DTO, program will write D11 and D10 into CR#3 and CR#2 of special module#0. It only writes a group of data in one time (n=1). The instruction will be executed when X0=On and it won’t be executed when X0=Off. The data that wrote in previous won’t have any change. X0 K0 K2 D0 DTO K1 Footnote The rule of instruction operand: m1: arrangement number of special module. The number of special module that connects to PLC MPU. The numbering order of special module from the near to the distant of MPU is from 0 to 7. The maximum is 8 special modules and won’t occupy I/O point. m2: the number of CR. Built in 16-bit of 49 groups memory of special module is called CR (Control Register). The number of CR uses decimal digital (#0~#48). All running status and setting values of special module has included. If using FROM/TO instruction, the unit of read/write of CR is one number for one time. If using DFROM/DTO instruction, the unit of read/write of CR is two numbers in one time. CR #10 CR #9 Upper 16-bit Lower 16-bit Specified CR number (Access16-bit if n=2, or 32-bit if n=1. Same controlled registers are accessed). D0 D1 D2 D3 D4 D5 CR #5 CR #6 CR #7 CR #8 CR #9 CR #10 D0 D1 D2 D3 D4 D5 CR #5 CR #6 CR #7 CR #8 CR #9 CR #10 Specified device Specified CR Specified device Specified CR 16-bit command when n=6 32-bit command when n=3 In ES series models, flag M1083 is not provided. When FROM/TO instruction is executed, all interrupts (including external or internal interrupt subroutines) will be disabled. All interrupts will be executed after completing FROM/TO instruction. Besides, FROM/TO instruction also can be executed in the interrupt subroutine. The function of the flag M1083 (FROM/TO mode exchange) provided in EP/EH series models: a. When M1083=Off, all interrupts (including external or internal interrupt subroutines) will be disabled when FROM/TO instruction is executed. The Interrupts will resumed after FROM/TO instruction complete. Please be advised FROM/TO instruction can be executed in the interrupt subroutine. b. When M1083=On, if an interrupt enable occurs while FROM/TO instruction are executing, the interrupt FROM/TO instruction will be blocked till the requested interrupt finish. Unlike M1080 off situation, FROM/TO instruction cannot be executed in the interrupt subroutine. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |