công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

GPBA01B bảng dữ liệu(PDF) 8 Page - Generalplus Technology Inc.

tên linh kiện GPBA01B
Giải thích chi tiết về linh kiện  Bus Extender
PDF  29 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  GENERALPLUS [Generalplus Technology Inc.]
Trang chủ  http://www.generalplus.com
Logo GENERALPLUS - Generalplus Technology Inc.

GPBA01B bảng dữ liệu(HTML) 8 Page - Generalplus Technology Inc.

Back Button GPBA01B Datasheet HTML 4Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 5Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 6Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 7Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 8Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 9Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 10Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 11Page - Generalplus Technology Inc. GPBA01B Datasheet HTML 12Page - Generalplus Technology Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 29 page
background image
GPBA01B
© Generalplus Technology Inc.
Proprietary & Confidential
8
MAY 28, 2007
Version: 1.1
6.5. Daisy Chain
There are 11 pins connecting from MPU to BEX, except MC0, MC1,
and AD bus.
In addition, there is another pin, named CI, the
Cascade-In of BEX.
When CI goes from low to high, the VID/SID
of BEX will be reset and must be setup.
When accessing BEX,
the CI pin must keep in logical high level.
Both CI and CO provide the circuitry to concatenate up to seven
BEX.
In such case, the CO (Cascade-Out) of the former BEX is
connected to the CI of next BEX to form a daisy-chain.
After CI of
1
st BEX goes from low to high, the 1st setting of Volume ID, VID,
(setting $000DH) will apply to the 1
st BEX. After the 1st BEX is
configured, it will raise its CO.
The CO of the 1
st
BEX is
connected with the CI of the 2
nd BEX; as a result, the configuration
will apply to the 2
nd BEX, and…etc.
CO
MC[1:0]
AD[7:0]
BEXA
CI
OUT
MC[1:0]
AD[7:0]
MPU
CO
MC[1:0]
AD[7:0]
BEXB
CI
2
0
0
0
0
For correction operation, if there are 5 BEXs on the system, issue
exactly five unique VID.
After all VID have been set, any writing activity to $000D will be
taken as “selecting”.
For example, after setting the VID of the
BEXs as 1, 2, 3... up to 7, simply write 3 to $000DH to select and
access it when MPU intends to access BEX of ID 3.
Note that the sequence of ID is not necessary of 1, 2, 3...7.
The
user is allowed to set the IDs as 3, 2, 1... or 7,2,4... Just keep in
mind that the 1
st ID is applied to the 1st BEX in the daisy chain. The
0 is not a valid ID.
Because we want all BEXs to share the same BMI, every BEX
needs two variables, Volume-ID (VID) and Select-ID (SID) inside.
We must send unique VID to every BEX and then we should
choose one of these BEX by setting SID.
At any time, only one
BEX can operate
.
Which BEX will be activated depending on
which BEX has VID=SID (but VID cannot be 0).
$000DH register
is used for set both VID and SID, but VID can be written once only.
When MPU sends OUT=0, CI of BEXA=0 causes VID, SID, CO of
BEXA=0, too; CO of BEXA always causes VID, SID, CO of
BEXB=0.
Finally, all functions in these two GPBA01B are
disabled and all registers remain at the previous states, except
volume-id (VID) and select-id (SID), which are reset to zero.
6.5.1. Example
We will describe the action of two BEX on the daisy chain as
follows.
It’s important that MPU shares bus with BEXs.
How can
we identify BEX and send a unique VID to each BEX? It is
achieved by CI and CO.
CO
MC[1:0]
AD[7:0]
BEXA
CI
OUT
MC[1:0]
AD[7:0]
MPU
CO
MC[1:0]
AD[7:0]
BEXB
CI
2
0
0
0
0
VID =0
SID=0
VID =0
SID=0
$000DH
register works for setting a unique VID for each BEXs, and
then acts as SID only.
VID are write-once register.
The first step
is accessing BEXA and then accessing BEXB as follows:
1.
MPU’s OUT=0
2.
MPU’s OUT=1
3.
Send_addr_data($000d,$03)
; Set 3 to VID of BEXA(VID write once)
4.
Send_addr_data($000d,$05)
; Set 5 to VID of BEXB(VID write once)
5.
Send_addr_data($000d,$03)
; Set 3 to SID of BEXA and BEXB
(BEXA active, BEXB inactive)
6.
Send_addr_data($0023,$XX)
; Configure BEXA as ‘Memory extender’ or ‘I/O extender’
7.
(Access BEXA….)
8.
…..
9.
Send_addr_data($000d,$05)
; Set 5 to SID of BEXA and BEXB
(BEXA inactive, BEXB active)
10. Send_addr_data($0023,$XX)
; Configure BEXB as ‘Memory extender’ or ‘I/O extender’
11. (Access BEXB…..)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com