2 / 3 page ![]() 2 Technical Data 10339 Effective November 2017 XL60 Supercapacitors Cylindrical cells www.eaton.com/electronics Ratings Capacitance 3000 F to 3400 F Maximum working voltage 2.70 V / 2.85 V Surge voltage 2.85 V / 3.00 V Capacitance tolerance 0% to +20% Operating temperature range -40 °C to +65 °C Extended operating temperature range -40 °C to +85 °C (with voltage derating to 2.30 V / 2.45 V @ +85 °C) Specifications Capacitance1 (F) Part Number Maximum working voltage (V) Maximum initial ESR1 (mΩ) Nominal leakage current2 (mA) Stored energy3 (Wh) Peak power4 (W) Pulse current5 (A) Continuous current6 (A) Typical thermal resistance7 Rth (°C/W) Short circuit current8 (A) 3000 XL60-2R7308W-R 2.70 0.23 5.0 3.0 7,900 2,400 143 3.2 11,700 3000 XL60-2R7308T-R 2.70 0.23 5.0 3.0 7,900 2,400 143 3.2 11,700 3400 XL60-2R9348W-R 2.85 0.23 8.0 3.8 8,800 2,700 143 3.2 12,400 3400 XL60-2R9348T-R 2.85 0.23 8.0 3.8 8,800 2,700 143 3.2 12,400 Performance Parameter Capacitance Change (% of initial value) ESR (% of initial maximum value) Lifetime — 1,500 hours at maximum rated voltage and operating temperature ≤ 20% ≤ 200% Charge/discharge cycling9 — 1 million at +25 °C ≤ 20% ≤ 200% Storage, uncharged, up to +35 °C — 3 years ≤ 5% ≤ 10% 1. Capacitance, Equivalent Series Resistance (ESR) and Leakage current are measured according to IEC62391-1 with current in milliamps (mA) = 8 x C x V. 2. Leakage current at +20 °C after 72 hour charge and hold. 3. Stored Energy (Wh) = 0.5 x C x V2 3600 4. Peak Power (W) = V2 4 x ESR 5. Pulse current for 1 second from full rate voltage to half voltage.(A) = 0.5 x V x C (1 + ESR x C) 6. Continuous current with a 15 °C temperature rise. Continuous current (A) = 7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W). 8. Short circuit current is for safety information only. Do not use as operating current. 9. Cycling between maximum working voltage and half voltage with 3 seconds rest at +25 °C, 100 A. Safety and Certifications Agency information UL Recognized (3000 F), Guide BBBG2, File MH46887 Shock and vibration IEC 61373 Category 1, Class B, IEC 60068-2-6 Safety UL 810A Environmental RoHS compliant, lead free, halogen free Altitude, Operating 10,000 ft Altitude, Non-operating 40,000 ft |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |