| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TE28F320B3BC90 bảng dữ liệu(PDF) 17 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
TE28F320B3BC90 bảng dữ liệu(HTML) 17 Page - Intel Corporation |
|
17 / 58 page ![]() 28F004/400B3, 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3UHOLPLQDU\ 11 3.2.2 Read Identifier To read the manufacturer and device codes, the device must be in read identifier mode, which can be reached by writing the Read Identifier command (90H). Once in read identifier mode, A0 = 0 outputs the manufacturer’s identification code and A0 = 1 outputs the device identifier (see Table 5) Note: A1–A21 = 0. To return to read array mode, write the Read Array command (FFH). 3.2.3 Read Status Register The device status register indicates when a program or erase operation is complete and the success or failure of that operation. To read the status register issue the Read Status Register (70H) command to the CUI. This causes all subsequent read operations to output data from the status register until another command is written to the CUI. To return to reading from the array, issue the Read Array (FFH) command. The status register bits are output on DQ0–DQ7. The upper byte, DQ8–DQ15, outputs 00H during a Read Status Register command. The contents of the status register are latched on the falling edge of OE# or CE#. This prevents possible bus errors which might occur if status register contents change while being read. CE# or OE# must be toggled with each subsequent status read, or the status register will not indicate completion of a program or erase operation. When the WSM is active, SR.7 will indicate the status of the WSM; the remaining bits in the status register indicate whether or not the WSM was successful in performing the desired operation (see Table 7 on page 14). 3.2.3.1 Clearing the Status Register The WSM sets status bits 1 through 7 to “1,” and clears bits 2, 6 and 7 to “0,” but cannot clear status bits 1 or 3 through 5 to “0.” Because bits 1, 3, 4 and 5 indicate various error conditions, these bits can only be cleared through the Clear Status Register (50H) command. By allowing the system software to control the resetting of these bits, several operations may be performed (such as cumulatively programming several addresses or erasing multiple blocks in sequence) before Table 5. Read Identifier Table Size Mfr. ID Device Identifier -T (Top Boot) -B (Bottom Boot) 28F004B3 0089H D4H D5H 28F400B3 8894H 8895H 28F008B3 0089H D2H D3H 28F800B3 8892H 8893H 28F016B3 D0H D1H 28F160B3 0089H 8890H 8891H 28F320B3 8896H 8897H 28F640B3 8898H 8899H |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |