Back Button AL1673 Datasheet HTML 4Page - Diodes Incorporated AL1673 Datasheet HTML 5Page - Diodes Incorporated AL1673 Datasheet HTML 6Page - Diodes Incorporated AL1673 Datasheet HTML 7Page - Diodes Incorporated AL1673 Datasheet HTML 8Page - Diodes Incorporated AL1673 Datasheet HTML 9Page - Diodes Incorporated AL1673 Datasheet HTML 10Page - Diodes Incorporated AL1673 Datasheet HTML 11Page - Diodes Incorporated AL1673 Datasheet HTML 12Page - Diodes Incorporated Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 15 page
background image
AL1673
Document number: DS39540 Rev. 1 - 2
8 of 15
www.diodes.com
April 2017
© Diodes Incorporated
AL1673
Functional Description and Application Information (Cont.)
Protections
1. Output Open Protection (OVP)
The output voltage is reflected by the volt
age on transformer’s auxiliary winding. Both FB pin and VCC pin of IC integrate over voltage protection
function. When there is a rapid line and load transient, the output voltage may exceed the regulated value. If VCC exceeds VCC_OVP or VFB
exceeds VFB_CV, the over voltage protection will be triggered, switch will be turned off and VCC will be discharged. Once VCC is below VOPR_MIN.
the IC will shut down and be powered on again by BUS voltage through start up resistor.
Thus, output over voltage depends o
n the minimum voltage between both OVP protections’ limitation. It can be gotten by below formula.
__
56
,
6
SS
OVP
CC OVP
FB CV
AUX
AUX
NN
RR
V
Min
V
V
N
N
R



------------------------------ (2)
Where VOVP is the output over voltage setting; R5 and R6 that is shown as Figure 1, it is the resistor divider from auxiliary winding;
NAUX is the turns of auxiliary winding; NS is turns of the secondary winding. VCC_OVP is OVP Voltage of VCC.
2. Output short protection (OSP)
When the output is shorted, the output voltage is clamped to zero. The output voltage of the auxiliary winding, which is proportional to the output
winding, will drop down too. Once VCC is below VOPR_MIN, the IC will shut down and power on again by the BUS voltage through the start up
resistor.
3. Over Current Protection (OCP)
The AL1673 has a build-in cycle by cycle over current protection of primary inductor current. When CS pin voltage reaches the voltage VCS_OCP,
switch will be turned off until next switch period. The maximum peak current (IPEAK (MAX)) of the inductor can be calculated as below:
_
CS OCP
PEAK MAX
CS
V
I
R
------------------------------ (3)
Where VCS_OCP means primary current clamp voltage that is 1.2V.
RCS is current sense resister which is shown as Figures 1 and 2.
4. Thermal Fold-back Protection (TFP)
The AL1673 has thermal fold-back function: it adopts self-adaptive control method which can prevent the system from breaking down caused by
over temperature. The overheating temperature is set at +145°C. When the temperature of the IC is higher than this point; the device will decrease
the voltage reference of the CS linearly till OTP happens. By this way, the device can limit system’s input power at high ambient temperature,
preventing system’s temperature increases further.
5. Over Temperature Protection (OTP)
The AL1673 has build-in over temperature protection (OTP) function. When the temperature goes up to +165°C, the over temperature protection
will be triggered, which leads to a latch mode protection. When OTP happens, the system need to be powered off and on again to restart.
Output Constant-current Control
According to the definition of mean output current, the mean output current can be obtained as below.
dt
t
t
I
I
SW
ONS
SP
MEAN
O
0
_
2
1
1
------------------------------ (4)
Where IO_MEAN is the mean output current; ISP is secondary peak current of transformer;
tONS is discharge time of secondary side of transformer; tSW is the switch period.
According to the principle of AL1673 close loop control, the voltage of RCS will be sampled when switch is turned off and the value will be held until
discharge time tONS is over. It can be described by following formula:



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com