| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
305C21 bảng dữ liệu(PDF) 2 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
305C21 bảng dữ liệu(HTML) 2 Page - Vishay Siliconix |
|
2 / 6 page ![]() www.vishay.com 4 305C Series Vishay Cera-Mite ceramite.support@vishay.com Document Number: 23086 Revision 14-May-02 The use of a PTCR start assist insures sufficient acceleration torque to overcome not only breakaway friction, but also parasitic asynchronous torques associated with the 5th and 7th motor harmonics or lamination slot harmonics. ACCELERATION TIME CONSIDERATIONS The time to accelerate a rotating machine is: RPM x WK 2 (lb ft2) Accelerating Time (Seconds) = Avg. Torque (lb ft) x 308 (Avg. Torque = Curve B - Curve A) 1. If (Curve B - Curve A) is zero or less, the motor may stall. 2. In calculating torque available from Curve B, allowance should be made for cusps in the torque curve due to harmonics. The time needed to accelerate from rest to 1/2 speed is critical, as the average torque available in this region is limited. Select a PTCR with sufficient switching time (t) to accelerate the compressor. 3. Scroll and rotary compressors may have less breakaway torque than shown. 4. A compressor with no equalization may require over 100% starting torqe and time as long as several seconds. PTCR starters not recommended. Fig T-4 Fig T-6 Simplified Voltage Diagram of the PSC Motor at Operating Speed *IA (auxiliary current) leads IM (main current) by 80° to 90° when C (run capacitor) is chosen for balanced operation at 3/4 to full load. Line Power Factor = sine 2 θ Fig T-5 PTCR Motor Start Packages HP x 746 IL (run) = IL (start) ≈ 6 x IL run VM x pf x eff For running conditions: IL If Vaux = VM, then IM and Iaux = √2 I L VM VM If Vaux ≠ VM, then Iaux = x and Zaux = √2 Vaux Iaux For the greatest starting torque, PTCR should be chosen to make: VM x IM = Vaux x Iaux. In many cases the auxiliary Volt- Amperes are limited to about 50% of the main winding Volt-Amperes to get 50% - 70% rated torque. Then at start, with PTCR in series: Z'aux = RPTCR + Zaux VM IR start through PTCR = Z'aux VM 1 IC start through Run Cap = ; Xc = ohms Xc 2 πfC Iaux start = IR start + IC start If Zaux is low impedance, less than 10% of RPTCR then it can be ignored and IPTCR at start = VM RPTCR This closely approximates the condition for motors over 1/2 HP. START AND ACCELERATION TORQUES SINGLE PHASE PSC HIGH EFFICIENCY COMPRESSORS CONSIDERATIONS FOR CURRENT IN PTCR APPROXIMATE EQUIVALENT CIRCUIT PSC MOTOR AT ZERO SPEED 100 75 50 25 0 5th 7th Slot 100 200 A2 A1 B1 B 2 Line Voltage VM Iaux IM Ic RM * XM * L 2 C PTCR Xaux Raux *R and X are total of stator and rotor Vaux L 1 IL IR CURVE B2 Motor speed versus torque with run cap and PTCR CURVE B1 Motor speed versus torque with run cap only CURVE A2 Torque req’d to accelerate compressor at partial differential pressure CURVE A1 Torque req’d to accelerate unloaded compressor Cold Breakaway Torque Percent Rated Torque Full Load Operating Point Possible Region of Harmonic Torques max. Torque VA θ IA IM VM Applied Voltage V PTCR = V C = I A C θ ∗ ∗ |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |