| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
L8200G-P16-R bảng dữ liệu(PDF) 5 Page - Unisonic Technologies |
|
|
|||||||||||||||||||||||||||||
L8200G-P16-R bảng dữ liệu(HTML) 5 Page - Unisonic Technologies |
|
5 / 6 page ![]() L8200 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 5 of 6 www.unisonic.com.tw QW-R123-017.G T Y PI CAL APPLI CAT I ON CI RCU I T UTC L8200 G1 D1 D2 G2 VOUT HB LB CSUB JF1 C* L* C1 10nF L* C* C2 10nF * Stripline Elements 22k Ω 22k Ω 47nF To other FET stages Power supply for IF Amps RL1 RH1 RL2 QL CL1 RH2 9.75GHz Local Osc. 10.6GHz Local Osc. QH CH1 LNB power and tone signal Capacitors C1 and C2 ensure that residual power supply and substrate generator noise is not allowed to affect other external circuits which may be sensitive to RF interference. They also serve to suppress any potential RF feed through between stages via the UTC L8200. These capacitors are required for all stages used. Values of 10nF and 4.7nF respectively are recommended however this is design dependent and any value between 1nF and 100nF could be used. The capacitor CSUB is an integral part of the UTC L8200 ’s negative supply generator. The negative bias voltage is generated on-chip using an internal oscillator. The required value of capacitor CSUB is 47nF. This generator produces a low current supply of approximately -3V. Although this generator is intended purely to bias the external FETs, it can be used to power other external low current circuits via the CSUB pin. Resistor RCALA sets the drain current at which all external amplifier FETs are operated and RCALM sets the mixer bias current. If any bias control circuit is not required, its related drain and gate connections may be left open circuit without affecting the operation of the remaining bias circuits. The UTC L8200 have been designed to protect the external FETs form adverse operating conditions. With a JFET connected to any bias circuit, the gate output voltage of the bias circuit can not exceed the range -3.0V~1V under any conditions, including power up and power down transients. Should the negative bias generator be shorted or overloaded so that the drain current of the external FETs can no longer be controlled, the drain supply to FETs is shut down to avoid damage to the FETs by excessive drain current. UTC L8200 incorporates over and under voltage protection so is the receiver or installation develops a fault the LNB will shut down and restart once operating conditions are back to normal. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |