công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

MLX90371 bảng dữ liệu(PDF) 12 Page - Melexis Microelectronic Systems

tên linh kiện MLX90371
Giải thích chi tiết về linh kiện  Daughter Board for Melexis PTC devices
PDF  14 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  MELEXIS [Melexis Microelectronic Systems]
Trang chủ  http://www.melexis.com
Logo MELEXIS - Melexis Microelectronic Systems

MLX90371 bảng dữ liệu(HTML) 12 Page - Melexis Microelectronic Systems

Back Button MLX90371 Datasheet HTML 6Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 7Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 8Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 9Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 10Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 11Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 12Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 13Page - Melexis Microelectronic Systems MLX90371 Datasheet HTML 14Page - Melexis Microelectronic Systems  
Zoom Inzoom in Zoom Outzoom out
 12 / 14 page
background image
PTC04-DB-HALL06
Daughter Board for Melexis PTC devices
PTC04-DB-HALL06
Page 12 of 14
Data Sheet
Rev. 2.0 (Preliminary)
April 15
1.5. Jumper Selection
1.5.1.
CON18 and CON19
– short measuring lines
The D-SUP DB-25 connector of the daughter
board is equipped with a sensing line for each
analog device pin.
The top row is the force line of the device pins.
The bottom row is the sensing line of the device
pins.
Between each force and sense line there is a
jumper to short the sense line at the DB-25
connector on the daughter board.
The jumper is placed when the external sensing
is not required. For example: an application with
a digital or PWM output.
Figure 13: Jumper between force and sense line.
Figure 14: DB-25 device connector.
CON18 and CON19 are used to short the force
and sense line of the analog device pins.
In other words, they are used to select single
wire or double wire connection to the pin of the
module / sensor.
CON18  Device / Die A
CON19  Device / Die B
D-SUB DB-25
Connector
VDDA
VDD_Sens
Module
Connector
VDD
CJ
Single wire connection
When de jumper is closed, only one wire is
required per pin between the PTC-04 and the
module or sensor.
In the table above these pins are marked as
“Minimum required single/dual die connection”.
In this configuration the measurement of VDD,
OUT1 or OUT2 is done at the D-SUB DB-25
connector of the PTC04-DB-HALL06.
D-SUB DB-25
Connector
VDDA
VDDA_Sens
Module
Connector
VDD
OJ
Double wire connection
When de jumper is open, two wires are required
per pin between the PTC-04 and the module or
sensor.
With two wires connected at the module side,
the measurement of VDD, OUT1 or OUT2 is
done on the module or sensor connector.
The external sensing line per pin is only required
for applications with an analog sensor output
and where a higher measuring accuracy is
required.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com