40 / 91 page ![]() ZL8802 FN8760 Rev.3.00 Page 40 of 91 Nov 8, 2017 OT_FAULT_LIMIT (4Fh) Definition: Sets the temperature at which the device should indicate an over-temperature fault. Paged or Global: Paged Data Length in Bytes: 2 Data Format: Linear-11 Type: R/W Protectable: Yes Default Value: EBE8h (+125°C) Units: Celsius Equation: OT_FAULT_LIMIT = Y×2N Range: 0 to 175°C OT_FAULT_RESPONSE (50h) Definition: Instructs the device on what action to take in response to an over-temperature fault. The retry time is the time between restart attempts. Paged or Global: Paged Data Length in Bytes: 1 Data Format: Bit Field Type: R/W Protectable: Yes Default Value: BFh (Continuous retries, retry delay 280ms) Units: Retry time unit = 35ms COMMAND OT_FAULT_LIMIT (4Fh) Format Linear-11 Bit Position 15 14 13 12 11 10 98 76 54 321 0 Access R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W Function Signed Exponent, N Signed Mantissa, Y Default Value 1 11 01 011 11 10 100 0 COMMAND OT_FAULT_RESPONSE (50h) Format Bit Field Bit Position 76 5 4321 0 Access R/WR/W R/WR/W R/WR/W R/WR/W Function See Following Table Default Value 1 0 1 1111 1 BIT FIELD NAME VALUE DESCRIPTION 7:6 Response behavior, the device: •Pulls SALRT low • Sets the related fault bit in the status registers. Fault bits are only cleared by the CLEAR_FAULTS command. 00-01 Not used 10 Disable and Retry according to the setting in Bits [5:3]. 11 Output is disabled while the fault is present. Operation resumes and the output is enabled when the temperature falls below the OT_WARN_LIMIT. 5:3 Retry Setting 000 No retry. The output remains disabled until the fault is cleared. 001-110 Not used 111 Attempts to restart continuously, until it is commanded OFF (by the ENABLE pin or OPERATION command or both), bias power is removed, or another fault condition causes the unit to shut down. A retry is attempted after the temperature falls below the OT_WARN_LIMIT. The time between the start of each attempt to restart is set by the value in Bits [2:0] multiplied by 35ms. 2:0 Retry Delay 000-111 Retry delay time = (Value +1)*35ms. Sets the time between retries in 35ms increments. Range is 35ms to 280ms. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |