| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TLE4998C8D bảng dữ liệu(PDF) 18 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE4998C8D bảng dữ liệu(HTML) 18 Page - Infineon Technologies AG |
|
18 / 27 page ![]() TLE4998C8(D) SPC Output Data Sheet 18 Revision 1.1, 2017-01 7.4 SPC Modes SPC enables the use of enhanced protocol functionality due to the ability to select between “synchronous”, “range selection” and “ID selection” protocol mode. The ID register is only used in ID selection mode. 7.4.1 Synchronous Transmission In the “synchronous” mode, the sensor (slave) starts to transfer a complete data frame only after a low pulse is forced by the master on the OUT pin. This means that the data line is bidirectional - an open drain output of the micro controller (master) sends the trigger pulse. The sensor then initiates a sync pulse and starts to calculate the new output data value. After the synchronization period, the data follows in form of a standard SENT frame, starting with the status, data and CRC nibbles. At the end, an end pulse allows the CRC nibble decoding and indicates that the data line is idle again. The timing diagram in Figure 7-1 visualizes a synchronous transmission. Figure 7-3 Bidirectional Communication in Synchronous Mode 7.4.2 Synchronous Transmission Including Range Selection The low time duration of the master can be used to select the magnetic range of the sensor in SPC dynamic range selection mode. Table 7-5 SPC Mode Selection Mode Parameter Prot MSB Parameter Prot LSB Synchronous 0 No effect Dynamic range selection 1 0 ID selection 1 1 Table 7-6 Master Pulse Timing for Synchronous Mode Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Master low time t mlow 1.5 2.75 4 UT1) 1) UT = Programmed nominal SPC unit time. – Table 7-7 Master Pulse Timing for Dynamic Range Mode Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Master low time t mlow 1.5 3.25 5 UT1) 1) UT = Programmed nominal SPC unit time. Range = 200 mT ( R=0) 9 12 15 UT Range = 100 mT ( R=1) 24 31.5 39 UT Range = 50 mT ( R=3) Sensor CPU VDD OUT GND Capcom-Unit Outpin (OD) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |