| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
RAC02-3.3SE bảng dữ liệu(PDF) 3 Page - Recom International Power |
|
|
|||||||||||||||||||||||||||||
RAC02-3.3SE bảng dữ liệu(HTML) 3 Page - Recom International Power |
|
3 / 4 page ![]() PA-3 REV.: 8/2017 www.recom-power.com AC/DC Converter ENVIRONMENTAL Parameter Condition Value Operating Temperature Range (5) 230VAC, with derating (see graph) -40°C to +85°C Maximal Case Temperature +105°C Thermal Impedance 8.5°C/W typ. Humidity non-condensing 5% - 95%, RH max. MTBF (6) MIL-HDBK-217F G.B., +25°C 115VAC 230VAC 2238 x 103 hours 1670 x 103 hours -40 60 70 75 80 85 90 100 50 40 30 20 10 0 -20 -25 0 20 40 60 50 80 100 Ambient Temperature [°C] @ 85-140VAC 3.3V and 5V all other models -40 60 70 75 80 85 90 100 50 40 30 20 10 0 -20 0 20 40 60 50 80 100 Ambient Temperature [°C] @ 140-305VAC all models Derating Graph Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) RAC02-SE/277/W Series SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety (LVD) LVD1208051 IEC60950-1, 2nd Edition, 2009 EN60950-1, 2nd Edition, 2011 Information Technology Equipment, General Requirements for Safety E224736-X1-A24 UL60950-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition 2014 Household and similar electrical appliances, General requirements L0339L26-B2 EN60335-1, 2014 EMC Compliance Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Report: 1502CE17 EN55022, Class B EN55024 ESD Electrostatic discharge immunity test ±8kV Air Discharge; ±6kV Contact EN61000-4-2, Criteria B Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3, Criteria A Fast Transient and Burst Immunity AC Power Port: ±1kV EN61000-4-4, Criteria B Surge Immunity AC Power Port: line to line: ±1kV EN61000-4-5, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port: 3V/m EN61000-4-6, Criteria A Power Magnetic Field Immunity 1 A/m EN61000-4-8, Criteria A Voltage Dips and Interruption Voltage Dips: >95% reduction >30% reduction Interruption: >95% EN61000-4-11, Criteria B EN61000-4-11, Criteria C EN61000-4-11, Criteria C Voltage Fluctuations and Flicker in Public Low-Voltage Systems EN61000-3-3 Notes: Note5: At low input voltage (85-140VAC) and temperature below -25°C the RAC02-3.3SE/277/W and RAC02-05SE/277/W, will not start. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |