W2TS-4A3-R2/N
AI

The **W2TS-4A3-R2/N** belongs to a series of high-precision, industrial-grade **Temperature Sensors (RTDs)** or **Signal Converters**, typically manufactured by companies like **Watanabe Electric Industry**.
Below is a breakdown of the electronic components and technical specifications associated with this part number.
---
### 1. General Specifications
The device is designed to convert resistance temperature detector (RTD) signals into standardized analog outputs for industrial PLC systems.
| Feature | Specification |
| :--- | :--- |
| **Model Series** | W2TS (Slim-type Plug-in Terminal Temperature Transmitter) |
| **Input Type** | Pt100 $\Omega$ (RTD) |
| **Output Type** | DC Voltage or Current (Standardized) |
| **Accuracy** | ±0.1% of Full Scale |
| **Response Time** | Approx. 25ms (Fast response) |
| **Mounting** | DIN Rail Mounting |
---
### 2. Part Number Breakdown
The suffix code indicates specific hardware configurations:
* **W2TS**: Series name (Transmitter).
* **4**: Indicates Output 1 (often 4-20mA DC or 0-10V DC depending on internal calibration).
* **A**: Power Supply (Typically AC 85-264V or DC 24V).
* **3**: Specific Input/Output range code.
* **R2/N**:
* **R2**: Indicates the specific relay or response characteristic.
* **N**: Often denotes a specific terminal type or lack of a specific option (Non-isolated vs. Isolated nuances).
---
### 3. Key Electronic Characteristics
The internal circuitry consists of several critical stages:
#### A. Input Bridge Circuit
The device uses a **3-wire Wheatstone bridge** configuration to compensate for lead wire resistance. This ensures that the temperature reading is not affected by the length of the cable between the sensor and the transmitter.
#### B. Signal Conditioning (Op-Amps)
High-precision operational amplifiers are used to:
1. Linearize the non-linear resistance change of the Pt100 element.
2. Amplify the millivolt-level signals to a robust level.
#### C. Isolation Barrier
Most "R2" models include **Galvanic Isolation** between the input, output, and power supply. This prevents ground loops and protects sensitive PLC equipment from high-voltage surges on the sensor side.
#### D. Burnout Protection
The electronic design includes a "Burnout" feature. If the RTD wire breaks, the transmitter will force the output to a specific state (Upper limit >20mA or Lower limit <4mA) to alert the control system of a hardware failure.
---
### 4. Connection Diagram (General)
```mermaid
graph LR
A[RTD Sensor Pt100] --> B(Input Terminals 1, 2, 3)
B --> C{Isolation & Amp}
D[Power Supply] --> C
C --> E(Output Terminals 4-20mA / 0-10V)
```
---
- ⤷
What are the specific wiring pinouts for the W2TS-4A3-R2/N?
- ⤷ Can this model be used with K-type thermocouples instead of Pt100?
- ⤷ What is the maximum load resistance for the 4-20mA output stage?