công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

  • W2TS-32A-R2/N

  • AI
    The **W2TS-32A-R2/N** is a high-performance **Automatic Transfer Switch (ATS)** module typically used in industrial and data center power distribution units (PDUs). It is designed to ensure power redundancy by automatically switching between two power sources (Primary and Backup). --- ## 1. Technical Specifications The part number indicates specific electronic and electrical characteristics: | Feature | Specification | | :--- | :--- | | **Rated Current** | 32 Amps | | **Voltage Range** | 200V - 240V AC (Standard Single Phase) | | **Switching Time** | Typically < 10-15ms (Fast enough for most IT loads) | | **Poles** | 2-Pole (Line and Neutral) | | **Mounting** | Rack-mount or DIN-Rail compatible variants | --- ## 2. Key Electronic Components The internal architecture of the W2TS-32A-R2/N consists of several critical electronic sub-systems: ### A. Sensing Circuitry (Microprocessor Controlled) * **Voltage Monitoring:** High-precision resistors and ADCs (Analog-to-Digital Converters) monitor the input voltage of both Source A and Source B. * **Phase Detection:** Ensures the switch occurs safely regarding the synchronization of the AC waveform. ### B. Switching Mechanism (Relay/Thyristor Hybrid) * **Electromechanical Relays:** Provide the physical isolation and high current carrying capacity. * **Snubber Circuits:** RC (Resistor-Capacitor) networks protect the contacts from arcing during the transition of 32A loads. ### C. Logic and Control * **MCU (Microcontroller):** Processes the logic for "Source Preference." If Source A fails or drops below a voltage threshold (Undervoltage), the MCU triggers the gate to switch to Source B. * **LED Indicators:** Integrated circuitry for visual status reporting (Source A Active, Source B Active, Fault). --- ## 3. Connectivity and Interface The "R2/N" suffix often refers to the communication and wiring configuration: * **Dry Contacts:** Often includes a terminal block for remote monitoring (sending a signal to a Building Management System if a power failure occurs). * **Input/Output Terminals:** Heavy-duty screw terminals designed to handle 8AWG to 10AWG wiring necessary for a 32A continuous load. --- ## 4. Safety and Protection Features 1. **Break-Before-Make (BBM) Logic:** The electronic control ensures Source A is disconnected before Source B is connected, preventing a short circuit between the two power grids. 2. **Surge Protection:** Internal MOVs (Metal Oxide Varistors) protect the sensitive internal logic from voltage spikes. 3. **Isolation:** High dielectric strength between control electronics and the high-power path.
    ✨ Follow-up Questions
    • ⤷ What is the typical MTBF (Mean Time Between Failure) for this ATS model?
    • ⤷ Can the W2TS-32A be integrated into an SNMP-managed network for remote monitoring?
    • ⤷ What is the specific difference between the R2 and R1 versions of this component?