W2TS-311-R2
AI

The **W2TS-311-R2** is a specific model within the **W2TS series of Digital Temperature Controllers**, typically manufactured by companies like **Hanyoung Nux** or similar industrial automation providers. These devices are designed for precise thermal management in industrial environments.
---
### 1. Core Technical Specifications
The W2TS-311-R2 is characterized by its input/output configuration and its physical form factor.
| Feature | Specification |
| :--- | :--- |
| **Control Type** | ON/OFF Control or Proportional Control |
| **Input Type** | Thermocouple (K, J) or RTD (Pt100Ω) |
| **Output Type** | **Relay Output** (indicated by the "R" in the suffix) |
| **Power Supply** | 100 - 240V AC (50/60 Hz) |
| **Display** | 3-Digit or 4-Digit LED (Process Value/Set Value) |
| **Dimensions** | Usually 72(W) x 72(H) mm or 48(W) x 48(H) mm (DIN Standard) |
---
### 2. Key Electronic Components & Internal Architecture
The device functions through a series of integrated electronic stages:
#### A. Input Stage (Sensor Interface)
* **Analog-to-Digital Converter (ADC):** Converts the millivolt signal from a thermocouple or the resistance change from an RTD into a digital signal.
* **Cold Junction Compensation (CJC):** An internal thermistor that compensates for the temperature at the controller’s terminals to ensure accurate thermocouple readings.
#### B. Control Logic (Microcontroller)
* **MCU:** The "brain" that compares the Process Value (PV) against the Set Value (SV).
* **Hysteresis Logic:** In ON/OFF mode, the MCU applies a "dead band" to prevent the relay from "chattering" (rapidly switching) when the temperature is exactly at the set point.
#### C. Output Stage (Power Control)
* **Electromechanical Relay:** The "R2" designation specifically refers to the relay contact output. This acts as a physical switch to turn a heater or cooler on and off.
* **Rating:** Typically rated for 250V AC / 3A or 5A (Resistive Load).
---
### 3. Connection Terminal Guide
The rear of the unit features a terminal block usually mapped as follows:
1. **Power Terminals:** Connection for AC mains power.
2. **Sensor Terminals:**
* For **Thermocouples**: Polarized (+ and -).
* For **RTD (Pt100)**: Usually 3-wire (A, B, b) to compensate for lead wire resistance.
3. **Output Terminals:** Common (COM), Normally Open (NO), and sometimes Normally Closed (NC) contacts for the relay.
---
### 4. Common Applications
* **Plastic Processing:** Controlling heat in injection molding machines.
* **Food Industry:** Maintaining oven or fryer temperatures.
* **Packaging:** Heat-sealing bars for plastic bags.
* **HVAC:** Industrial cooling or heating system regulation.
- ⤷
How do I wire a Pt100 RTD sensor to the W2TS-311-R2?
- ⤷ What is the difference between the Relay output (R) and an SSR output (S) model?