W2RS-613-R
AI

The **W2RS-613-R** is a specific model of a **Miniature Intermediate Power Relay**, typically manufactured by companies like **Wago** or **Dinkle** (often associated with interface modules). It is designed to bridge the gap between low-power control signals (like those from a PLC) and higher-power loads.
---
### 1. Technical Specifications
The "613" designation usually refers to the internal relay configuration and voltage ratings. Below are the typical electronic specifications for this part:
| Feature | Specification |
| :--- | :--- |
| **Relay Type** | Electromechanical Relay |
| **Contact Configuration** | 1 Changeover (SPDT - Single Pole Double Throw) |
| **Input (Coil) Voltage** | 24V DC (Common for this series) |
| **Max Switching Voltage** | 250V AC / 30V DC |
| **Rated Current** | 6A to 10A (Depending on specific load type) |
| **Mounting Type** | DIN Rail (35mm) via Socket |
| **Connection Technology** | Push-in or Screw Terminals |
---
### 2. Internal Electronic Components
The device is more than just a mechanical switch; it contains several electronic safety and functional parts inside the housing:
* **The Coil (Inductor):** When energized with 24V DC, it creates a magnetic field to pull the physical contacts together.
* **The Armature/Contacts:** Silver Alloy (AgSnO2) is typically used for the contact points to ensure high conductivity and resistance to "welding" under load.
* **Protection Diode (Flyback Diode):** Most "R" suffix models include an integrated freewheeling diode across the coil to protect the driving PLC/Controller from voltage spikes when the relay is turned off.
* **LED Status Indicator:** A built-in green or red LED provides visual confirmation that the control circuit is active.
---
### 3. Wiring Diagram Logic
The terminal numbering follows standard industrial relay patterns:
```text
Input Side (Control):
A1 (+) : Positive 24V DC
A2 (-) : Negative / Ground
Output Side (Load):
11 (COM) : Common Terminal
12 (NC) : Normally Closed
14 (NO) : Normally Open
```
---
### 4. Key Applications
* **Signal Isolation:** Protecting sensitive PLC outputs from high-voltage surges in the field.
* **Current Amplification:** Using a small 20mA control signal to switch a 6A motor or heater.
* **Voltage Conversion:** Controlling a 230V AC device using a 24V DC control system.
- ⤷